...
首页> 外文期刊>Journal of the Association of Physicians of India >Accuracy of Filter Paper Method for Measuring Glycated Hemoglobin
【24h】

Accuracy of Filter Paper Method for Measuring Glycated Hemoglobin

机译:滤纸法测定糖化血红蛋白的准确性

获取原文
           

摘要

Background and Objectives: Glycated hemoglobin (HbA1c) provides an accurate and reliable method to assess the glycemic control in patients with Diabetes. Its measurement is limited by the inconvenience of sample collection that requires venipuncture, sample handling and storage factors. The aim of this study was to assess the feasibility of using a dried capillary blood spot on a filter paper to estimate HbA1c, to check its stability at room temperature and to compare these values with the venous sample HbA1c by Turbidimetric Inhibition Immunoassay (TINA, Tina-quant HbA1c II). Methods : Venous blood samples of seventy eight patients with Type 1 or type 2 diabetes, were collected in EDTA containing vacutainers. Stability of HbA1c was studied in capillary blood samples blotted on to Whatman number1 filter paper and stored at room temperature, for the first 20 patients enrolled in the study. After establishing the stability over a ten day period, HbA1c values obtained on the capillary blood spots were compared with those obtained from the venous blood samples of the remaining 58 patients. Results : Glycated hemoglobin is found to be stable in dried capillary blood spots on filter paper till the 10th day, stored at room temperature. It however, shows an inherent variability of μ15%, which falls with in the permissible variability (18%) of the quality control material. Seventy nine percent of the capillary HbA1c values were found to fall within this range. With linear regression, we derived the relationship between filter paper and venous HbA1c values. The regression equation was as follows: Cap.HbA1c = 0.95 (Ven.HbA1c) + 1.4. The filter paper results were highly correlated with the venous sample values (r = 0.889, p < 0.01). Conclusion : Measurement of glycated hemoglobin in dried blood spots on filter paper gives reliable and reproducible results. In our study, the mean capillary sample HbA1c value was 12% higher compared to the venous sample HbA1c values. Therefore a higher normal range may have to be used for interpreting the dried blood spot capillary blood HbA1c values.
机译:背景与目的:糖化血红蛋白(HbA1c)提供了一种准确可靠的方法来评估糖尿病患者的血糖控制。它的测量受到需要静脉穿刺,样品处理和存储因素的不便样品采集的限制。这项研究的目的是评估在滤纸上使用干燥的毛细血管血斑评估HbA1c的可行性,检查其在室温下的稳定性以及通过比浊抑制免疫分析法(TINA,Tina)将这些值与静脉血HbA1c进行比较的可行性。 -定量HbA1c II)。方法:在包含真空容器的EDTA中收集78例1型或2型糖尿病患者的静脉血样本。在研究的前20名患者中,在吸到Whatman 1号滤纸上并保存在室温下的毛细血管血样中研究了HbA1c的稳定性。在建立了十天的稳定性之后,将在毛细血管血斑上获得的HbA1c值与从其余58例患者的静脉血样品中获得的值进行比较。结果:糖化血红蛋白在滤纸上干燥的毛细血管血斑中可稳定到第10天,并在室温下保存。但是,它显示出μ15%的固有变异性,与质量控制材料的容许变异性(18%)相同。发现有百分之九十九的毛细管HbA1c值落在该范围内。通过线性回归,我们得出滤纸与静脉HbA1c值之间的关系。回归方程如下:Cap.HbA1c = 0.95(Ven.HbA1c)+ 1.4。滤纸结果与静脉样本值高度相关(r = 0.889,p <0.01)。结论:在滤纸上测量干血斑中的糖化血红蛋白可得到可靠且可重复的结果。在我们的研究中,平均毛细血管样本Hb​​A1c值比静脉样本HbA1c值高12%。因此,可能必须使用更高的正常范围来解释干血斑毛细血管血HbA1c值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号