Boiling heat transfer to analysis of effect main plate initial temperature to rewetting characteristics that arerewetting time, and pattern of rewetting were studied from transient temperature of surface plate. It is as result of experimentusing two vertical plate with 1 mm narrow gap. Debit and temperature of cooling water were controlled about 0,09 lt/s andsaturated temperature. The initial temperatures of main plate were changed from 500°C, 550°C, and 600°C. As results shownthat midle part of main plat has the highest value of rewetting time that is 310 second at 600°C initial main platetemperature, the lowest rewetting time is 40 second at 500oC initial main plate temperature on the bottom part of plate. Thehigher the plate initial temperature, the longer the rewetting time and variation of the plate initial temperatures can notinfluent the pattern of rewetting.
机译:从平板的瞬态温度研究了沸腾传热,以分析影响主板初始温度到再润湿时间的再润湿特性,以及再润湿的方式。这是使用两个间隙为1 mm的垂直板进行实验的结果。冷却水的借方和温度控制在约0.09 lt / s和饱和温度。主板的初始温度从500°C,550°C和600°C更改。结果表明,在600°C的初始主板温度下,主板中部的再润湿时间最高,为310秒;在500oC的初始主板温度下,基板的最低再润湿时间为40秒。板初始温度越高,再润湿时间越长,并且板初始温度的变化不会影响再润湿的模式。