Interest in pollution issues caused by synthetic dye wastewater is growing. For many years, researchers have attempted to develop more efficient treatment technology to solve this long-standing environmental problem. As many related studies have focused on advanced oxidation processes (AOPs), the plasma process is remarkable due to its high decolorization efficiency over a short time. This study applied a plasma process in the form of pulsed discharge to treat dye wastewater and to investigate the decolorization of dye wastewater over time by manipulating operation parameters. This method is expected to provide a rapid and highly efficient decolorization technology for wastewater treatment. The results indicate that 99%, 98%, 95% and 73% decolorization could be achieved for methylene blue solutions with initial concentrations of 1 ppm, 5 ppm, 10 ppm, and 20 ppm, respectively, after the experimental device was operated for one hour with operation parameters set at 100 mL min-1 for air inflow, an initial pH of 2.5 for pollutants, and 10 KV for output voltage, while other parameters were fixed.
机译:对由合成染料废水引起的污染问题的兴趣正在增长。多年来,研究人员一直试图开发更有效的处理技术来解决这一长期存在的环境问题。由于许多相关研究都集中在高级氧化工艺(AOP)上,等离子体工艺因其在短时间内的高脱色效率而引人注目。本研究采用脉冲放电形式的等离子体工艺处理染料废水,并通过操纵操作参数研究染料废水随时间的脱色。该方法有望为废水处理提供快速高效的脱色技术。结果表明,在实验装置运行1次后,初始浓度分别为1 ppm,5 ppm,10 ppm和20 ppm的亚甲基蓝溶液可分别实现99%,98%,95%和73%的脱色。运行时间设置为每小时100 mL min-1(空气流入),初始pH值为2.5(污染物)和10 KV(输出电压),而其他参数是固定的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号