首页> 外文期刊>Journal of Young Pharmacists >Metabolite Profiling Analysis of Conventional and Non-Conventional Extraction Methods on Secondary Metabolite from Peperomia pellucida (L.) Kunth Using UPLC-QToF-MS/MS System
【24h】

Metabolite Profiling Analysis of Conventional and Non-Conventional Extraction Methods on Secondary Metabolite from Peperomia pellucida (L.) Kunth Using UPLC-QToF-MS/MS System

机译:使用UPLC-QToF-MS / MS系统分析传统和非常规提取方法对白粉病菌次生代谢物的代谢物谱分析

获取原文
       

摘要

Objective: The purpose of this study was to observe the difference of extraction method (both conventional and non-conventional) based on metabolite profile using UPLC-QToF-MS/MS system from Peperomia pellucida (L.) Kunth. Methods: Dried samples were extracted using the conventional maceration method and the optimum ofionic liquid-based microwave-assisted extraction (IL-MAE) methods.Metabolite profiling was performed using UPLC-QToF-MS/MS system with some modifications adjusted to the instrument condition. The data was analyzed using Masslynx 4.1 software. Results: based on the results, there were differences on metabolite profiling from both conventional and non-conventional extraction methods that was extraction method using organic solvent and ionic liquid solvent ([BMIM]BF4 at the optimum condition.The extract obtained using IL-MAE method had a peak depth with a well-separated Rt (retention time) value ranging from 0.5 to 7.5 min which means that the extracted compound was from polar to nonpolar properties. The extract obtained using maceration method, the peak spread on a separate Rt ranges from 2.5 to 7.5 min. Also, both extracts obtained have different area under curve (AUC) values with amount total of 22285 (IL-MAE) and 12679 (maceration), respectively, and showed the IL-MAE twice as large as that of the maceration. Conclusion: based on the results, conventional and non-conventional extraction method showed differences in metabolite profiling based on Rt value and mass spectrum m/z of each peak.
机译:目的:本研究的目的是使用Peperomia pellucida(L.)Kunth的UPLC-QToF-MS / MS系统观察基于代谢物谱图的提取方法(常规方法和非常规方法)的差异。方法:采用常规浸渍法和最佳的离子液体微波辅助萃取法(IL-MAE)提取干燥样品。使用UPLC-QToF-MS / MS系统进行代谢物分析,并根据仪器条件进行一些修改。使用Masslynx 4.1软件分析数据。结果:根据结果,与常规和非常规提取方法(在最佳条件下使用有机溶剂和离子液体溶剂([BMIM] BF4]进行提取的方法)的代谢物谱图存在差异。采用IL-MAE提取的提取物方法的峰深度在0.5至7.5分钟之间有一个很好的Rt(保留时间)值分离,这意味着所提取的化合物具有极性至非极性性质,采用浸软法获得的提取物的峰在不同的Rt范围内扩散从2.5到7.5分钟,所获得的两种提取物的曲线下面积(AUC)值也不同,总量分别为22285(IL-MAE)和12679(浸渍),并且显示出IL-MAE的两倍。结论:基于结果,常规和非常规提取方法显示出基于每个峰的Rt值和质谱m / z进行的代谢物分析的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号