首页> 外文期刊>Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine >Reliability and Validity of In Vitro Volume Calculations by 3-Dimensional Ultrasonography Using the Multiplanar, Virtual Organ Computer-Aided Analysis (VOCAL), and Extended Imaging VOCAL Methods
【24h】

Reliability and Validity of In Vitro Volume Calculations by 3-Dimensional Ultrasonography Using the Multiplanar, Virtual Organ Computer-Aided Analysis (VOCAL), and Extended Imaging VOCAL Methods

机译:使用多平面,虚拟器官计算机辅助分析(VOCAL)和扩展成像VOCAL方法通过三维超声检查进行体外体积计算的可靠性和有效性

获取原文
           

摘要

Objective. The purpose of this study was to assess the reliability and validity of in vitro volume calculations by 3-dimensional ultrasonography. Methods. This observational study was performed by 2 examiners to obtain volumes of 3 objects of different shapes and sizes filled with ultrasound gel and immersed in water. The examiners used the multiplanar (5-mm interval), virtual organ computer-aided analysis (VOCAL, 30°) and extended imaging (XI) VOCAL (5, 10, 15, and 20 planes) methods to estimate the volumes of each object. A paired Student t test (P) and intraclass correlation coefficients (ICCs) were used to assess reproducibility of the methods. Validity was assessed comparing the percent differences between the estimated and the real volumes using the P value, mean differences, and ICC for each method. Results. All methods were highly reliable and valid. There were no significant differences in interobserver variability; there was a strong interobserver correlation. There were no significant differences in the percent differences between the estimated and real volumes of the objects using the 3 methods. The XI VOCAL method was superior to the multiplanar and VOCAL methods in the measurement of irregularly shaped objects. The XI VOCAL method with 10 planes estimated volumes closest to the real volumes. Conclusions. All 3 methods were reliable and valid; however, XI VOCAL was superior to the other methods in the measurement of irregularly shaped objects.
机译:目的。这项研究的目的是通过3维超声检查来评估体外体积计算的可靠性和有效性。方法。这项观察性研究由2位检查员进行,以获取3个不同形状和大小的物体的体积,这些物体填充有超声波凝胶并浸入水中。检查人员使用多平面(间隔为5毫米),虚拟器官计算机辅助分析(VOCAL,30°)和扩展成像(XI)VOCAL(5、10、15和20个平面)方法来估计每个对象的体积。配对的学生t检验(P)和组内相关系数(ICC)用于评估方法的可重复性。使用每种方法的P值,均值差和ICC比较估计值和实际体积之间的百分比差异,对有效性进行评估。结果。所有方法都是高度可靠和有效的。观察者间的变异性无显着差异。观察者之间存在很强的相关性。使用3种方法估算的对象体积与实际体积之间的百分比差异没有显着差异。在测量不规则形状的物体时,XI VOCAL方法优于多平面和VOCAL方法。具有10个平面的XI VOCAL方法估计的体积最接近实际体积。结论。这三种方法都是可靠有效的。但是,XI VOCAL在测量不规则形状的物体方面优于其他方法。

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号