首页> 外文期刊>Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine >Novel Use of Ultrasound Elastography to Quantify Muscle Tissue Changes After Dry Needling of Myofascial Trigger Points in Patients With Chronic Myofascial Pain
【24h】

Novel Use of Ultrasound Elastography to Quantify Muscle Tissue Changes After Dry Needling of Myofascial Trigger Points in Patients With Chronic Myofascial Pain

机译:超声弹性成像技术在慢性肌筋膜痛患者干针注射肌筋膜触发点后定量使用肌肉组织变化的新方法

获取原文
           

摘要

Objectives To compare a mechanical heterogeneity index derived from ultrasound vibration elastography with physical findings before and after dry‐needling treatment of spontaneously painful active myofascial trigger points in the upper trapezius muscle. Methods Forty‐eight patients with chronic myofascial pain enrolled in a prospective interventional trial of 3 weekly dry‐needling treatments for active myofascial trigger points. Trigger points were evaluated at baseline and at treatment completion using palpation, the pressure‐pain threshold, and the mechanical heterogeneity index. Thirty patients were reevaluated at 8 weeks. Trigger points that “responded” changed to tissue that was no longer spontaneously painful, with or without the presence of a palpable nodule. Trigger points that “resolved” changed to tissue without a palpable nodule. The mechanical heterogeneity index was defined as the proportion of the upper trapezius muscle that appeared mechanically stiffer on elastography. Statistical significance for comparisons was determined at P & .05. Results Following 3 dry needle treatments, the mechanical heterogeneity index decreased significantly for the 38 myofascial trigger points (79% of 48) that responded to treatment. Among these, the baseline mechanical heterogeneity index was significantly lower for the 13 trigger points (27% of 38) that resolved, but the decrease after 3 dry needle treatments did not reach significance. The pressure‐pain threshold improved significantly for both groups. At 8 weeks, the mechanical heterogeneity index decreased significantly for the 22 trigger points (73% of 30) that responded and for the 10 (45% of 22) that resolved. The pressure‐pain threshold improvement was significant for trigger points that responded but did not reach significance for resolved trigger points. Conclusions The mechanical heterogeneity index identifies changes in muscle tissue properties that correlate with changes in the myofascial trigger point status after dry needling.
机译:目的比较超声振动弹性成像得出的机械异质性指数与干针治疗斜方肌上肌自发性主动肌筋膜触发点前后的物理表现。方法对38例慢性肌筋膜痛患者进行一项前瞻性干预试验,该试验每周进行3次干针治疗,以检测肌筋膜活跃触发点。在基线和治疗结束时使用触诊,压力疼痛阈值和机械异质性指标评估触发点。 30例患者在第8周重新评估。 “响应”的触发点变为不再伴有明显结节的自发疼痛的组织。 “已解决”的触发点变为无明显结节的组织。机械异质性指数定义为弹性成像上机械上较硬的上斜方肌的比例。比较的统计显着性确定为P <0。 .05。结果经过3次干针治疗后,对治疗有反应的38个肌筋膜触发点(48个中的79%)的机械异质性指数显着降低。其中,基线的机械异质性指标在已解决的13个触发点上显着降低(占38个中的27%),但经过3次干针治疗后的降低并未达到显着水平。两组的疼痛痛阈值均显着改善。在第8周时,响应的22个触发点(占30%的73%)和解决的10个触发点(占22%的45%)的机械异质性指数显着降低。对于响应的触发点,压力疼痛阈值的改善是显着的,但对于已解决的触发点,压力疼痛阈值的改善并不显着。结论机械异质性指数可识别肌肉组织特性的变化,该变化与干针后肌筋膜触发点状态的变化相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号