首页> 外文期刊>Journal of Rehabilitation Research and Development >Does a waist-worn ActiGraph accelerometer quantify community ambulation in persons with multiple sclerosis?
【24h】

Does a waist-worn ActiGraph accelerometer quantify community ambulation in persons with multiple sclerosis?

机译:腰部佩戴的ActiGraph加速度计是否可以量化多发性硬化症患者的社区活动?

获取原文
       

摘要

Accelerometry has been recognized as a method of objectively measuring community ambulation in persons with multiple sclerosis (MS). However, the assumption that walking itself serves as a major contributor to the accelerometer signal has yet to be tested. This study examined the assumption that communitybased walking is a primary contributor to accelerometer output in MS. Ambulatory persons (5 males/17 females; 13 without aid/9 with aid) with MS wore a triaxial accelerometer (ActiGraph GT3X, Health One Technologies; Fort Walton Beach, Florida) as well as an IDEEA system (MiniSun, Inc; Fresno, Florida) over the course of a single day. Outcome measures for the accelerometer included movement counts/hour for the vertical, anteriorposterior, and mediolateral axes. Outcomes for the IDEEA system included percent time walking, sitting, and standing, as well as walking speed. Pearson product correlations (r) were used to examine the associations between outcomes from the accelerometer and IDEEA system. Significant correlations were observed between percent walking time and movement counts/hour along the vertical (r = 0.84) and anteriorposterior (r = 0.69) axes. Significant correlations were further noted between movement counts/hour along the vertical axis and walking speed (r = 0.45) and selfreport walking impairment (r = ?0.50) and disability (r = ?0.46). Such observations further support accelerometry as an objective marker of community ambulation in persons with MS.
机译:加速度计已被公认为是客观测量多发性硬化症(MS)患者社区活动的一种方法。但是,关于行走本身是加速度计信号的主要贡献者这一假设尚未得到检验。这项研究检验了以下假设:基于社区的步行是MS中加速度计输出的主要贡献者。装有MS的步行者(5名男性/ 17名女性; 13名无助/ 9名有助)戴着三轴加速度计(ActiGraph GT3X,Health One Technologies; Fort Walton Beach,佛罗里达州)和IDEEA系统(MiniSun,Inc; Fresno,佛罗里达)。加速度计的结果度量包括垂直,前后和中间轴的运动计数/小时。 IDEEA系统的结果包括步行,就坐和站立的时间百分比以及步行速度。皮尔逊产品相关性(r)用于检查加速度计和IDEEA系统的结果之间的关联。在沿垂直轴(r = 0.84)和前后轴(r = 0.69)的步行时间百分比和运动计数/小时之间观察到显着相关性。沿垂直轴的运动计数/小时与步行速度(r = 0.45),自我报告的步行障碍(r =≤0.50)和残疾(r =≤0.46)之间还存在显着的相关性。这样的观察进一步支持加速度计作为MS患者社区移动的客观标志。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号