...
首页> 外文期刊>Journal of Pharmacy and Bioallied Sciences >Evaluation of Microhardness of Residual Dentin in Primary Molars Following Caries Removal with Conventional and Chemomechanical Techniques: An In vitro Study
【24h】

Evaluation of Microhardness of Residual Dentin in Primary Molars Following Caries Removal with Conventional and Chemomechanical Techniques: An In vitro Study

机译:用常规和化学机械技术评估龋齿去除后原发磨牙中残留牙本质的显微硬度:一项体外研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background: Many patients consider removal of caries to be a very unpleasant experience. Removal of caries with conventional drill is considered traumatic mainly due to fear and anxiety of children and their parents. Minimally invasive dentistry adopts a philosophy that integrates prevention, remineralization, and minimal intervention for the placement and replacement of restorations, thus reaching the treatment objective using the least invasive surgical approach, with the removal of the minimal amount of healthy tissues. Chemomechanical caries removal (CMCR) is a method for minimally invasive, gentle dentin caries removal based on biological principles which is an effective alternative to the traditional method. The present study was done to compare the microhardness of sound dentin before and after carious removal using a chemomechanical method and a conventional method. Materials and Methods: The present in vitro study was done on 28 proximal surfaces of fourteen extracted primary molars (with active caries on one proximal surface and sound side as control). The study was done to assess the Knoop microhardness of remaining dentinal surface after caries removal using a slow speed conventional bur and a chemomechanical method (Carie-Care?). Results and Conclusion: The rotary instrument group showed a consistent microhardness value with not much difference according to depth. The chemomechanical group showed a lesser microhardness value closer to the cavity floor than away from it. The microhardness values at all depths were significantly different for each treatment group with an increased value seen in the rotary group. The mean microhardness values of residual dentin in treated side were found to be insignificant when compared among each interval in each group. The microhardness of sound dentin had high significant difference from that of residual dentin in both the rotary group and the chemomechanical group. Keywords: Carie-Care? , chemomechanical caries removal , dentine , Knoop microhardness
机译:背景:许多患者认为去除龋齿是非常不愉快的经历。传统的钻头去除龋齿被认为是创伤性的,主要是由于儿童及其父母的恐惧和焦虑。微创牙科采用的理念是将预防,再矿化和最小干预整合在一起,以放置和更换修复体,从而使用微创外科手术方法达到治疗目的,同时去除最少量的健康组织。化学机械龋齿去除(CMCR)是一种基于生物学原理的微创,温和的牙本质龋齿去除方法,是传统方法的有效替代方法。本研究的目的是比较使用化学机械方法和常规方法进行龋齿去除前后声质牙本质的显微硬度。材料和方法:本体外研究是在14个拔除的第一磨牙的28个近端表面上进行的(其中一个活动龋齿位于一个近端表面上,而有声侧为对照组)。使用慢速常规钻针和化学机械方法(Carie-Care ?)评估了去除龋齿后残留牙本质表面的努氏显微硬度。结果与结论:旋转器械组的显微硬度值一致,根据深度差异不大。化学机械组显示出与腔底相近的显微硬度值小于远离腔底的显微硬度值。每个处理组在所有深度的显微硬度值均显着不同,而在旋转组中则有所增加。当在各组的每个间隔之间进行比较时,发现治疗侧残留牙本质的平均显微硬度值不明显。在旋转组和化学机械组中,有声牙本质的显微硬度与残余牙本质的显微硬度都有显着差异。关键词:Carie-Care ?,化学机械龋齿去除,牙本质,努氏显微硬度

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号