首页> 外文期刊>Journal of Pathology Informatics >Whole slide imaging for human epidermal growth factor receptor 2 immunohistochemistry interpretation: Accuracy, Precision, and reproducibility studies for digital manual and paired glass slide manual interpretation
【24h】

Whole slide imaging for human epidermal growth factor receptor 2 immunohistochemistry interpretation: Accuracy, Precision, and reproducibility studies for digital manual and paired glass slide manual interpretation

机译:用于人表皮生长因子受体2免疫组化的全玻片成像:数字手册和配对玻片手册解释的准确性,精密度和再现性研究

获取原文
           

摘要

Background:The use of digital whole slide imaging for human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) could create improvements in workflow and performance, allowing for central archiving of specimens, distributed and remote interpretation, and the potential for additional computerized automation.Procedures:The accuracy, precision, and reproducibility of manual digital interpretation for HER2 IHC were determined by comparison to manual glass slide interpretation. Inter- and intra-pathologist reproducibility and precision between the glass slide and digital interpretations of HER2 IHC were determined in 5 studies using DAKO HercepTest-stained breast cancer slides with the Philips Digital Pathology System. In 2 inter-method studies, 3 pathologists interpreted glass and digital slides in sequence or in random order with a minimum of 7 days as a washout period. These studies also measured inter-observer reproducibility and precision. Another two studies measured intra-pathologist reproducibility on cases read 10 times by glass and digital methods. One additional study evaluated the effects of adding IHC control slides with each run, using 1 pathologist interpreting glass and digital slides randomized from the sets above along with appropriate controls for each slide in the set.Results:The overall results show that there is no statistical difference between the variance of performance when comparing glass and digital HER2 interpretations; and there were no effects noted when control tissues were evaluated in conjunction with the test slides.Conclusions:The results show that there is an equivalence of result when interpreting HER2 IHC slides in breast cancer by either glass slides or digital images. Digital interpretation can therefore be safely and effectively used for this purpose.
机译:背景:对人类表皮生长因子受体2(HER2)免疫组织化学(IHC)使用数字全玻片成像可以改善工作流程和性能,从而实现标本的集中归档,分布式和远程解释,并有可能实现额外的计算机自动化程序:通过与手动载玻片解释进行比较,确定HER2 IHC手动数字解释的准确性,准确性和可重复性。在5项研究中,使用DAKO HercepTest染色的飞利浦数字病理系统,在玻璃载玻片和HER2 IHC的数字解释之间确定了病理学家之间和病理学家之间的可重复性和精度。在2种方法间研究中,3位病理学家按顺序或随机顺序解释了载玻片和数字载玻片,至少需要7天作为洗脱期。这些研究还测量了观察者之间的可重复性和准确性。另有两项研究通过玻璃和数字方法测量了10次阅读病例的病理学家的可重复性。另一项研究评估了每次运行中添加IHC对照玻片的效果,方法是由一名病理学家解释从上述组中随机分配的玻璃片和数字玻片,以及该组中每种玻片的适当对照。结果:总体结果表明,没有统计数据比较玻璃和数字HER2解释时的性能差异之间的差异;结论:结果表明,通过玻璃载玻片或数字图像解释HER2 IHC载玻片对乳腺癌的诊断结果是等效的。因此,数字解释可以安全有效地用于此目的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号