首页> 外文期刊>Journal of Physics: Conference Series >Features of the discharge ignition in the trigger unit of the cold-cathode thyratron
【24h】

Features of the discharge ignition in the trigger unit of the cold-cathode thyratron

机译:冷阴极晶闸管触发单元放电点火的特点

获取原文
           

摘要

The sealed-off cold-cathode thyratron TPI1-10k/50 type with a newly developed trigger unit based on auxiliary glow discharge is investigated. As distinct from the commercially produced sealed-off thyratrons, in the thyratron under investigation the high-emissivity tablet is not used. Features of ignition of the trigger discharge are considered. It has been revealed that the delay time to breakdown in the trigger unit and a jitter in the delay time decrease with an increase in working gas pressure. The delay time can be significantly decreased due to availability of the so-called parasitic current in the electrode system of trigger unit. A capability of the thyratron operation with a stability in delay time no more than 4 ns is demonstrated.
机译:研究了具有新开发的基于辅助辉光放电的触发单元的密封冷阴极晶闸管TPI1-10k / 50型。与商业生产的密封式闸流管不同,在所研究的闸流管中,未使用高发射率片剂。考虑触发放电的点火特性。已经发现,随着工作气体压力的增加,触发单元击穿的延迟时间和延迟时间的抖动减小。由于在触发单元的电极系统中可以利用所谓的寄生电流,因此可以大大减少延迟时间。展示了具有不超过4 ns的延迟时间稳定性的晶闸管工作能力。