The effects of emergency core coolant (ECC) temperature on the performance of the emergency core cooling system (ECCS) during a loss-of-coolant accident (LOCA) of a boiling water reactor (BWR) were investigated experimentally using the Rig of Safety Assessment (ROSA)-III integral test facility. The ECC temperature had no direct influence on the ECCS core cooling performance, since ECC became nearly saturated before reaching the core irrespective of the initial temperature, however, had indirect effects by changing the vessel pressure response. The ECCS injection timings and flow rates, and the core inlet flooding behavior were affected. The measured peak cladding temperature (PCT) was not affected by the ECC temperature for both large (200%) and small (5%) break tests.
机译:使用安全评估装备,通过实验研究了应急堆芯冷却剂(ECC)温度对沸水反应堆(BWR)的冷却剂丢失事故(LOCA)期间应急堆芯冷却系统(ECCS)性能的影响。 (ROSA)-III整体测试设备。 ECC温度对ECCS堆芯冷却性能没有直接影响,因为ECC在到达堆芯之前几乎已饱和,而与初始温度无关,但是通过改变容器压力响应而产生了间接影响。 ECCS的注入时间和流速,以及岩心入口驱油行为均受到影响。对于大(200%)和小(5%)断裂测试,测得的峰值包层温度(PCT)均不受ECC温度的影响。