Quantitative assessment of dopamine transporter imaging can aid in diagnosing Parkinson disease (PD) and assessing disease progression in the context of therapeutic trials. Previously, the software program SBRquant was applied to 123I-ioflupane SPECT images acquired on healthy controls and subjects with PD. Earlier work on optimization of the parameters for differentiating between controls and subjects with dopaminergic deficits is extended here for maximizing change measurements associated with disease progression on longitudinally acquired scans. Methods: Serial 123I-ioflupane SPECT imaging for 51 subjects with PD (conducted approximately 1 y apart) were downloaded from the Parkinson Progression Markers Initiative database. The software program SBRquant calculates the striatal binding ratio (SBR) separately for the left and right caudates and putamen regions of interest (ROIs). Parameters were varied to evaluate the number of summed transverse slices and the positioning of the striatal ROIs for determining the signal-to-noise ratio associated with their annual rate of change in SBR. The parameters yielding the largest change in the lowest putamen’s SBR from scan 1 to scan 2 were determined. Results: From scan 1 to scan 2 in the 51 subjects, the largest annual change was observed when the putamen ROI was placed 3 pixels away from the caudate and by summing 5 central striatal slices. This resulted in an 11.2% ± 4.3% annual decrease in the lowest putamen SBR for the group. Conclusion: Quantitative assessment of dopamine transporter imaging for assessing progression of PD requires specific, optimal parameters different from those for diagnostic accuracy.
机译:多巴胺转运蛋白成像的定量评估可以帮助诊断帕金森病(PD)和评估治疗试验中的疾病进展。以前,软件程序SBRquant应用于在健康对照组和PD受试者上获得的123I-碘伏SPECT图像。为了扩展与纵向获取的扫描上与疾病进展相关的变化测量值,这里扩展了关于优化参数以区分对照组和多巴胺能缺乏症受试者的早期工作。方法:从帕金森病进展标记倡议数据库中下载了51位PD患者的123I-ioflupane串行SPECT成像(相距约1年)。软件程序SBRquant分别计算左,右尾状和感兴趣的壳状核区域(ROI)的纹状体结合率(SBR)。改变参数以评估合计的横向切片的数量和纹状体ROI的位置,以确定与其SBR的年变化率相关的信噪比。确定了从扫描1到扫描2在最低的壳聚糖SBR中产生最大变化的参数。结果:在51位受试者中,从扫描1到扫描2,观察到最大的年度变化,是将壳核ROI放置在距尾状部3个像素处,并相加了5个中央纹状体切片。这导致该组最低的壳聚糖SBR每年下降11.2%±4.3%。结论:对多巴胺转运蛋白成像进行定量评估以评估PD进展需要与诊断准确性不同的特定,最佳参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号