Background class='Para'>A dual mobility cup has the theoretic potential to improve stability in primary total hip arthroplasty (THA) and mid-term cohort results are favorable. We'/> Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation: no dislocations in 50 hips after 1–5?years
首页> 外文期刊>Journal of orthopaedics and traumatology: official journal of the Italian Society of Orthopaedics and Traumatology >Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation: no dislocations in 50 hips after 1–5?years
【24h】

Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation: no dislocations in 50 hips after 1–5?years

机译:翻修性全髋关节置换术中双活动髋臼组件可导致持续性脱位:1-5年后50髋无脱位

获取原文
           

摘要

class="Heading">Background class="Para">A dual mobility cup has the theoretic potential to improve stability in primary total hip arthroplasty (THA) and mid-term cohort results are favorable. We hypothesized that use of a new-generation dual mobility cup in revision arthroplasty prevents dislocation in patients with a history of recurrent dislocation of the THA. class="Heading">Materials and methods class="Para">We performed a retrospective cohort study of patients receiving an isolated acetabular revision with a dual mobility cup for recurrent dislocation of the prosthesis with a minimum follow-up of 1?year. Kaplan–Meier survival analyses were performed with dislocation as a primary endpoint and re-revision for any reason as a secondary endpoint. class="Heading">Results class="Para">Forty-nine consecutive patients (50 hips) were included; none of the patients was lost to follow-up. The median follow-up was 29?months (range 12–66?months). Two patients died from unrelated causes. Survival after 56?months was 100?% based on dislocation and 93?% (95?% CI 79–98?%) based on re-revision for any reason. Radiologic analysis revealed no osteolysis or radiolucent lines around the acetabular component during the follow-up period. class="Heading">Conclusion class="Para">The dual mobility cup is an efficient solution for instability of THA with a favorable implant survival at 56?months. class="Heading">Level of evidence class="Para">Level 4, retrospective case series.
机译:class =“ Heading”>背景 class =“ Para”>双活动杯具有提高基本全髋关节置换术(THA)稳定性的理论潜力,中期队列研究结果令人满意。我们假设在翻修置换术中使用新一代双活动杯可防止有THA反复脱位史的患者脱位。 class =“ Heading”>材料和方法 我们进行了一项回顾性队列研究,研究对象是接受髋臼离体翻修并带有双活动杯的髋臼假体复发脱位的患者,其随访时间至少为1年。 Kaplan–Meier生存分析以脱位为主要终点,出于任何原因重新修订为次要终点。 class =“ Heading”>结果 class =“ Para”>包括49例连续患者(50髋);没有患者失去随访。中位随访时间为29个月(范围12-66个月)。 2例患者死于无关原因。由于任何原因,经脱位后56个月后的生存率为100%,而经重新修订则为93%(95%CI 79-98%)。放射学分析显示,在随访期间,髋臼周围没有骨溶解或射线可透线。 class =“ Heading”>结论 class =“ Para”>双活动杯是一种THA不稳定的有效解决方案,可在56个月时获得良好的种植体存活率。 class =“ Heading”>证据级别 class =“ Para”>级别4,回顾性病例系列。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号