Purpose. To estimate the treatment effectiveness of femtosecond-assisted laser in situ keratomileusis (FS-LASIK) and Toric implantable collamer lens (Toric ICL) for moderate and high astigmatism via vector analysis. Materials and Methods. The study involved 44 eyes from 44 patients who had a preoperative refractive cylinder ≥1.0 diopters (D) and underwent bilateral FS-LASIK or Toric ICL surgery. The examinations included corrected distance visual acuity measurement and subjective refraction before and 3 months after surgery. The astigmatic changes were estimated using vector analysis. Results. No statistically significant differences were found in cylindrical refraction and percentage of spherical equivalent within 0?D, ±0.50?D, ±1.00?D, and ±1.50?D between the FS-LASIK and Toric ICL groups at 3 months after surgery. The parameters of the vector analysis included intended refractive correction, surgically induced refractive correction, error vector, correction ratio, error ratio, error of magnitude, and error of angle, with no significant differences between the groups. However, error ratio the of the off-axis correction in the FS-LASIK and Toric ICL groups was 4.11?±?3.02 and 8.11?±?3.82, respectively, and the difference was significant (t?=??2.46, ). Conclusion. Both FS-LASIK and Toric ICL were effective for correcting moderate and high astigmatism, although Toric ICL might produce a larger error of angle than FS-LASIK when an off-axis correction occurs.
机译:目的。通过矢量分析评估飞秒辅助激光原位角膜磨镶术(FS-LASIK)和Toric植入式矫正镜(Toric ICL)对中度和高度散光的治疗效果。材料和方法。该研究涉及来自44例术前屈光度≥1.0屈光度(D)的患者的44只眼睛,并接受了双侧FS-LASIK或Toric ICL手术。检查包括矫正远视力测量和手术前后3个月的主观验光。使用矢量分析估计散光变化。结果。术后3个月,FS-LASIK和Toric ICL组之间在0?D,±0.50?D,±1.00?D和±1.50?D之内的柱面屈光度和球面等效百分比之间无统计学意义的显着差异。向量分析的参数包括预期的屈光矫正,手术引起的屈光矫正,误差向量,校正率,误差率,大小误差和角度误差,两组之间无显着差异。但是,FS-LASIK和Toric ICL组的离轴校正的误差比分别为4.11≤±3.02和8.11≤±3.82,并且差异是显着的(t≥2.46)。结论。 FS-LASIK和Toric ICL均可有效校正中度和高度散光,尽管在发生离轴校正时Toric ICL可能会产生比FS-LASIK更大的角度误差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号