Under the background of complicated interconnected network, the splitting criterion for accurately capturing the electrical center in real time is the prerequisite of power grid splitting. This paper studies the features of electric quantity in the electrical center in aspect of the instantaneous frequency, and proposes the out-of-step splitting criterion for power systems based on bus voltage frequency. Firstly, through the establishment and solution to the out-of-step model of the power grid, the analytical expression of the voltage frequency at any position is obtained in the out-of-step oscillation, and the voltage frequency features of electrical center and non-electrical center are analyzed in details. Then, this paper constructs the typical scene of migration of electrical center to study the change rules of voltage frequency. Finally, the splitting criterion based on bus voltage frequency is proposed as well as the instruction for use. This criterion is easy to be realized and can adapt to the migration of electrical center. Also it is free from the limits of power network structure and operational mode. Simulation results of CEPRI-36 system and interconnected network example of one actual region verify the accuracy and the effectiveness of the proposed criterion.
机译:在复杂的互连网络背景下,实时准确捕获电力中心的分裂准则是电网分裂的前提。从瞬时频率的角度研究了电气中心的电量特性,提出了基于母线电压频率的电力系统失步分断准则。首先,通过建立和解决电网失步模型,得到失步振荡中任意位置的电压频率解析表达式,并得到电中心和电网的电压频率特征。对非电中心进行详细分析。然后,构建电中心迁移的典型场景,研究电压频率的变化规律。最后,提出了基于母线电压频率的分压准则以及使用说明。该准则易于实现并且可以适应电气中心的迁移。而且它不受电网结构和运行模式的限制。 CEPRI-36系统的仿真结果以及一个实际区域的互连网络示例证明了所提出准则的准确性和有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号