AbstractIntroductionThe magnitude of intra- and inter-fractional variation in the set up of breast cancer patients treated with tangential megavoltage photon beams was investigated using an electronic portal imaging device (EPID).MethodsDaily cine-EPID images were captured during delivery of the tangential fields for ten breast cancer patients treated in the supine position. Measurements collected from each image included the central lung distance (CLD), central flash distance (CFD), superior axial measurement (SAM) and the inferior axial measurement (IAM). The variation of motion within a fraction (intra-fraction) and the variation between fractions (inter-fraction) was analysed to quantify set up variation and motion due to respiration.ResultsAltogether 3775 EPID images were collected from 10 patients. The effect of respiratory motion during treatment was 0.1 cm standard deviation (SD) in the anterior–posterior (AP) direction. The inter-fraction movement caused by variations in daily set up was larger at 0.28 cm SD in the AP direction. Superior–inferior (SI) variation was more difficult to summarise and proved unreliable as the measurements were taken to an ambiguous point on the images. It was difficult to discern true SI movement from that implicated by AP movement.ConclusionThere is minimal intra-fractional chest wall motion due to respiration during treatment. Inter-fractional variation was larger, however, on average it remained within departmental tolerance (0.5 cm) for set up variations. This review of our current breast technique provides confidence in the feasibility of utilising advanced treatment techniques (field-in-field, intensity modulated radiotherapy or volumetric modulated arc therapy) following a review of the current imaging protocol.
机译:摘要简介使用电子门禁成像设备(EPID)研究了采用切向兆伏光子束治疗的乳腺癌患者在部分和内部的差异幅度。方法十名仰卧位治疗的乳腺癌患者。从每个图像收集的测量值包括中心肺距离(CLD),中心闪光距离(CFD),上轴向测量(SAM)和下轴向测量(IAM)。分析了分数内的运动变化(分数内)和分数之间的变化(分数间),以量化呼吸引起的设置变化和运动。结果共采集了10例患者的3775张EPID图像。治疗期间呼吸运动的影响在前后(AP)方向上<0.1 cm标准偏差(SD)。在AP方向上,每日设置变化引起的分数间运动较大,为0.28 cm SD。由于对图像进行模糊测量时,上-下(SI)的变化更难以概括,并且被证明是不可靠的。很难从AP运动牵连中分辨出真正的SI运动。结论由于治疗过程中的呼吸作用,胸腔内壁的运动很少。分部间的差异较大,但平均而言,设置差异仍在部门公差(0.5 cm)之内。在对当前的成像方案进行回顾之后,对我们当前的乳房技术的回顾为使用先进的治疗技术(场中,强度调制放射疗法或体积调制弧光疗法)的可行性提供了信心。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号