Objective To evaluate the extraction force generated at different extubation angles using a manikin simulation and a randomized clinical trial. Methods Simulations were performed on a manikin to assess the force generated at extubation angles of 0°, 30°, 45°, 60°, 90° and 120° relative to the ground. The trial compared extraction force and changes in vital signs in patients undergoing general anaesthesia with tracheal intubation followed by extubation at 60° or 90°. Results The simulation study found that the extubation force was significantly lower at 45° and 60° than at all other extraction angles. In the trial, extubation at 60° resulted in significantly lower extraction force and systolic blood pressure elevation (n?=?23) than extubation at 90° (n?=?23). Conclusion Findings in a manikin simulation were confirmed by those of a randomized clinical trial, where extubation at 60° required less force than 90°, and was accompanied by less SBP elevation. Extubation at 60° is less invasive than extubation at 90°.
机译:目的使用人体模型模拟和随机临床试验评估在不同拔管角度下产生的拔出力。方法对人体模型进行仿真,以评估拔管相对于地面的角度为0°,30°,45°,60°,90°和120°时产生的力。该试验比较了在全身麻醉下先行气管插管,然后在60°或90°拔管的患者的拔出力和生命体征变化。结果仿真研究发现,在45°和60°时拔管力明显低于所有其他拔出角度。在该试验中,与90°拔管(n?=?23)相比,在60°拔管的拔出力和收缩压升高(n?=?23)明显更低。结论人体模型模拟中的发现得到了一项随机临床试验的证实,其中60°拔管所需的力小于90°,​​并且伴随的SBP升高也较小。与90°拔管相比,在60°拔管的侵入性较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号