Fast neutron imaging has a great potential as a nondestructive technique for testing large objects. The main factor limiting applications of this technique is detection technology, offering relatively poor spatial resolution of images and low detection efficiency, which results in very long exposure times. Therefore, research on development of scintillators for fast neutron imaging is of high importance. A comparison of the light output, gamma radiation sensitivity and spatial resolution of commercially available scintillator screens composed of PP/ZnS:Cu and PP/ZnS:Ag of different thicknesses are presented. The scintillators were provided by RC Tritec AG company and the test performed at the NECTAR facility located at the FRM II nuclear research reactor. It was shown that light output increases and the spatial resolution decreases with the scintillator thickness. Both compositions of the scintillating material provide similar light output, while the gamma sensitivity of PP/ZnS:Cu is significantly higher as compared to PP/ZnS:Ag-based scintillators. Moreover, we report which factors should be considered when choosing a scintillator and what are the limitations of the investigated types of scintillators.
机译:快速中子成像作为测试大型物体的非破坏性技术具有巨大的潜力。限制该技术应用的主要因素是检测技术,它提供相对较差的图像空间分辨率和较低的检测效率,这导致非常长的曝光时间。因此,研究用于中子快速成像的闪烁体非常重要。介绍了由不同厚度的PP / ZnS:Cu和PP / ZnS:Ag组成的市售闪烁屏的光输出,伽马辐射灵敏度和空间分辨率的比较。闪烁器由RC Tritec AG公司提供,并在位于FRM II核研究反应堆的NECTAR设施中进行了测试。结果表明,随着闪烁体厚度的增加,光输出增加,空间分辨率降低。闪烁材料的两种成分均提供相似的光输出,而PP / ZnS:Cu的伽马敏感性比基于PP / ZnS:Ag的闪烁器高得多。此外,我们报告了选择闪烁体时应考虑哪些因素,以及研究的闪烁体类型的局限性是什么。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号