首页> 外文期刊>Journal of Functional Biomaterials >Effect of a Particulate and a Putty-Like Tricalcium Phosphate-Based Bone-grafting Material on Bone Formation, Volume Stability and Osteogenic Marker Expression after Bilateral Sinus Floor Augmentation in Humans
【24h】

Effect of a Particulate and a Putty-Like Tricalcium Phosphate-Based Bone-grafting Material on Bone Formation, Volume Stability and Osteogenic Marker Expression after Bilateral Sinus Floor Augmentation in Humans

机译:颗粒状和类似腻子的磷酸三钙基骨移植材料对人双侧窦底底增强后骨形成,体积稳定性和成骨标记物表达的影响

获取原文
           

摘要

This study examines the effect of a hyaluronic acid (HyAc) containing tricalcium phosphate putty scaffold material (TCP-P) and of a particulate tricalcium phosphate (TCP-G) graft on bone formation, volume stability and osteogenic marker expression in biopsies sampled 6 months after bilateral sinus floor augmentation (SFA) in 7 patients applying a split-mouth design. 10% autogenous bone chips were added to the grafting material during surgery. The grain size of the TCP granules was 700 to 1400 μm for TCP-G and 125 to 250 μm and 500 to 700 μm (ratio 1:1) for TCP-P. Biopsies were processed for immunohistochemical analysis of resin-embedded sections. Sections were stained for collagen type I (Col I), alkaline phosphatase (ALP), osteocalcin (OC) and bone sialoprotein (BSP). Furthermore, the bone area and biomaterial area fraction were determined histomorphometrically. Cone-beam CT data recorded after SFA and 6 months later were used for calculating the graft volume at these two time points. TCP-P displayed more advantageous surgical handling properties and a significantly greater bone area fraction and smaller biomaterial area fraction. This was accompanied by significantly greater expression of Col I and BSP and in osteoblasts and osteoid and a less pronounced reduction in grafting volume with TCP-P. SFA using both types of materials resulted in formation of sufficient bone volume for facilitating stable dental implant placement with all dental implants having been in function without any complications for 6 years. Since TCP-P displayed superior surgical handling properties and greater bone formation than TCP-G, without the HyAc hydrogel matrix having any adverse effect on bone formation or graft volume stability, TCP-P can be regarded as excellent grafting material for SFA in a clinical setting. The greater bone formation observed with TCP-P may be related to the difference in grain size of the TCP granules and/or the addition of the HyAc.
机译:这项研究检查了含有磷酸三钙腻子支架材料(TCP-P)的透明质酸(HyAc)和颗粒状磷酸三钙(TCP-G)移植物对6个月活检样本中骨形成,体积稳定性和成骨标志物表达的影响应用裂口设计对7例患者进行了双侧窦底增大术(SFA)后。在手术过程中,将10%的自体骨屑添加到移植材料中。 TCP-G的TCP颗粒的粒径为700至1400μm,TCP-P的为125至250μm和500至700μm(比例1:1)。对活检进行处理,以进行树脂包埋切片的免疫组织化学分析。对切​​片进行I型胶原蛋白(Col I),碱性磷酸酶(ALP),骨钙素(OC)和骨唾液蛋白(BSP)染色。此外,通过组织形态学测定骨面积和生物材料面积分数。 SFA之后和6个月后记录的锥形束CT数据用于计算这两个时间点的移植物体积。 TCP-P显示出更有利的外科手术处理性能以及显着更大的骨面积分数和更小的生物材料面积分数。这伴随着Col I和BSP以及成骨细胞和类骨质中明显更高的表达,以及TCP-P移植量的减少幅度不那么明显。使用这两种类型的材料的SFA都可以形成足够的骨量,以促进稳定的牙科植入物放置,并且所有牙科植入物都已经运转了6年,没有任何并发​​症。由于TCP-P与TCP-G相比具有更好的手术处理性能和更大的骨形成,而HyAc水凝胶基质对骨形成或移植物体积稳定性没有任何不利影响,因此TCP-P在临床上可被视为SFA的优良移植材料设置。使用TCP-P观察到的更大的骨形成可能与TCP颗粒的粒径差异和/或HyAc的添加有关。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号