首页> 外文期刊>Journal of Environmental Health Science and Engineering >Influence of liquid and gas flow rates on sulfuric acid mist removal from air by packed bed tower
【24h】

Influence of liquid and gas flow rates on sulfuric acid mist removal from air by packed bed tower

机译:液体和气体流速对填充床塔从空气中去除硫酸雾的影响

获取原文
           

摘要

The possible emission of sulfuric acid mists from a laboratory scale, counter-current packed bed tower operated with a caustic scrubbing solution was studied. Acid mists were applied through a local exhaust hood. The emissions from the packed bed tower were monitored in three different categories of gas flow rate as well as three liquid flow rates, while other influencing parameters were kept almost constant. Air sampling and sulfuric acid measurement were carried out iso-kinetically using USEPA method 8. The acid mists were measured by the barium-thorin titration method. According to the results when the gas flow rate increased from 10 L/s to 30 L/s, the average removal efficiency increased significantly (p?3, respectively. L/G of 2–3 was recommended for designing purposes of a packed tower for sulfuric acid mists and vapors removal from contaminated air stream.
机译:研究了在实验室规模,用苛性碱洗涤溶液运行的逆流填充床塔中可能产生的硫酸雾。通过局部排气罩施加酸雾。填充床塔的排放物以三种不同的气体流量类别和三种液体流量类别进行监控,而其他影响参数几乎保持恒定。使用USEPA方法8等速进行空气采样和硫酸测量。通过钡-胸腺素滴定法测量酸雾。根据结果​​,当气体流量从10 L / s增加到30 L / s时,平均去除效率显着提高(分别为p?3。为设计填料塔,建议使用L / G为2-3)用于从受污染的气流中去除硫酸雾和蒸气。