...
首页> 外文期刊>Journal of Applied Oral Science >Effect of antibacterial agents on the surface hardness of a conventional glass-ionomer cement
【24h】

Effect of antibacterial agents on the surface hardness of a conventional glass-ionomer cement

机译:抗菌剂对常规玻璃离聚物水泥表面硬度的影响

获取原文
   

获取外文期刊封面封底 >>

       

摘要

In atraumatic restorative treatment (ART), caries removal with hand excavation instruments is not as efficient as that with rotary burs in eliminating bacteria under the glass ionomer cements (GICs). Thus, different antibacterial agents have been used in recent studies to enhance the antibacterial properties of the GICs, without jeopardizing their basic physical properties. OBJECTIVE: The objective of this study was to evaluate the effect of antibacterial agents on the surface hardness of a conventional GIC (Fuji IX) using Vickers microhardness [Vickers hardness number (VHN)] test. MATERIAL AND METHODS: Cetrimide (CT), cetylpyridinium chloride (CPC) and chlorhexidine (CHX) were added to the powder and benzalkonium chloride (BC) was added to the liquid of Fuji IX in concentrations of 1% and 2%, and served as the experimental groups. A control group containing no additive was also prepared. After the completion of setting reaction, VHN measurements were recorded at 1, 7, 15, 30, 60, and 90 days after storage in 37°C distilled water. A one-way ANOVA was performed followed by a Dunnett t test and Tamhane T2 tests and also repeated measurements ANOVA was used for multiple comparisons in 95% confidence interval. RESULTS: VHN results showed significant differences between the control and the experimental groups at all time periods (p<0.05 for all). Significant differences were observed between all study periods for individual groups (p<0.05). After 7 days, VHNs were decreased in all experimental groups while they continued to increase in the control group. BC and CHX groups demonstrated the least whereas CT and CPC groups exhibited most adverse effect on the hardness of set cements. CONCLUSIONS: Despite the decreased microhardness values in all experimental groups compared to the controls after 7 up to 90 days, incorporating certain antibacterial agents into Fuji IX GIC showed tolerable microhardness alterations within the limitations of this in vitro study.
机译:在无创伤修复治疗(ART)中,用手动挖掘工具去除龋齿的效果不如旋转钻去除玻璃离聚物胶结剂(GIC)下的细菌有效。因此,在最近的研究中已经使用了不同的抗菌剂来增强GIC的抗菌性能,而又不损害其基本物理性能。目的:本研究的目的是使用维氏显微硬度[维氏硬度值(VHN)]测试评估抗菌剂对常规GIC(Fuji IX)表面硬度的影响。材料与方法:向粉末中加入西曲美特(CT),十六烷基氯化吡啶鎓(CPC)和洗必泰(CHX),将苯扎氯铵(BC)加入浓度为1%和2%的Fuji IX液体中实验组。还制备了不含添加剂的对照组。固化反应完成后,将VHN测量值保存在37°C蒸馏水中后的1,7,15,30,60和90天。进行了单向方差分析,随后进行了Dunnett t检验和Tamhane T2检验,还使用重复测量的方差分析以95%置信区间进行多次比较。结果:VHN结果显示对照组和实验组在所有时间段之间均存在显着差异(所有p均<0.05)。各个组的所有研究期之间均观察到显着差异(p <0.05)。 7天后,所有实验组的VHN均降低,而对照组则持续升高。 BC和CHX组显示最少,而CT和CPC组显示对凝固水泥硬度的最大不利影响。结论:尽管在7至90天后所有实验组的显微硬度值均比对照组降低,但在本体外研究的范围内,将某些抗菌剂掺入Fuji IX GIC仍显示出可忍受的显微硬度变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号