Background and aims. The purpose of this study was to evaluate initial force and force decay of commercially available elastomeric ligatures and elastomeric separators in active tieback state in a simulated oral environment. Materials and methods. A total of 288 elastomeric ligatures and elastomeric separators from three manufacturers (Dentaurum, RMO, 3M Unitek) were stretched to 100% and 150% of their original inner diameter. Force levels were measured initially and at 3-minute, 24-hour, and 1-, 2-, 3- and 4-week intervals. Data were analyzed by univariate analysis of variance and a post hoc Tukey test. Results. The means of initial forces of elastomeric ligatures and separators from three above-mentioned companies, when stretched to 100% of their inner diameters, were 199, 305 and 284 g, and 330, 416, 330 g; when they were stretched to 150% of their inner diameters the values were 286, 422 and 375 g, and 433, 540 and 504 g, respectively. In active tieback state, 11?18% of the initial force of the specimens was lost within the first 3 minutes and 29?63% of the force decay occurred in the first 24 hours; then force decay rate decreased. 62?81% of the initial force was lost in 4 weeks. Although force decay pattern was identical in all the products, the initial force and force decay of Dentaurum elastomeric products were less than the similar products of other companies (P0.05). Under the same conditions, the force of elastomeric separators was greater than elastomeric ligatures of the same company. Conclusion. Regarding the force pattern of elastomeric ligatures and separators and optimal force for tooth movement, many of these products can be selected for applying orthodontic forces in active tieback state.
机译:背景和目标。这项研究的目的是评估在模拟的口腔环境中,在主动回拉状态下可商购的弹性体绑扎带和弹性体隔板的初始力和力衰减。材料和方法。来自三个制造商(Dentaurum,RMO,3M Unitek)的总共288个弹性体连接器和弹性体分离器被拉伸至其原始内径的100%和150%。最初以3分钟,24小时以及1、2、3和4周的间隔测量力量水平。数据通过方差的单变量分析和事后Tukey检验进行分析。结果。来自上述三个公司的弹性体绑扎带和分离器的初始力在拉伸到其内径的100%时为199、305和284 g,以及330、416、330 g;当它们拉伸到其内径的150%时,该值分别为286、422和375 g,以及433、540和504 g。在主动拉回状态下,试样的初始力在最初的3分钟内损失了11%至18%,而在最初的24小时内发生了29%至63%的力衰减。然后力衰减率降低。在4周内损失了62%至81%的初始力量。尽管所有产品的力衰减模式相同,但Dentaurum弹性体产品的初始力和力衰减小于其他公司的同类产品(P <0.05)。在相同条件下,弹性体分离器的力大于同一公司的弹性体连接器。结论。关于弹性绑扎带和分离器的作用方式以及牙齿运动的最佳作用力,可以选择许多此类产品以在主动回缩状态下施加正畸作用力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号