...
首页> 外文期刊>Journal of chiropractic medicine >Sensitivity and Specificity of Modified Bragard Test in Patients With Lumbosacral Radiculopathy Using Electrodiagnosis as a Reference Standard
【24h】

Sensitivity and Specificity of Modified Bragard Test in Patients With Lumbosacral Radiculopathy Using Electrodiagnosis as a Reference Standard

机译:以电诊断为参考标准的改良Bragard试验对腰ac神经根病患者的敏感性和特异性

获取原文

摘要

Objective The purpose of this study was to assess the diagnostic accuracy of a modified Bragard test compared with the straight leg raise (SLR) test in patients presenting with electrodiagnostic evidence of L5 and S1 nerve root compression. Methods This was a cross-sectional study conducted on 506 consecutive patients with signs and symptoms consistent with lumbosacral radiculopathy confirmed by electrodiagnostic study. Patients were evaluated from September 2013 to September 2015 in the physical medicine and rehabilitation outpatient clinic of Shahid Faghihi Teaching Hospital, Shiraz, Iran. The SLR test was investigated concomitantly to determine the sensitivity and specificity. Results Electrodiagnostic study findings indicated lumbosacral radiculopathy in 312 patients. Of these participants, 198 were positive on SLR testing, and of 114 SLR-negative patients, 79 were positive on Modified Bragard testing. Sensitivity of the Modified Bragard test was 69.3%, and specificity was 67.42%. Positive and negative predictive values were 73.15% and 63.16%, respectively. Positive likelihood ratio was 2.13, and negative likelihood ratio was 0.46. Diagnostic odds ratio was 4.63. In patients with symptom duration of less than 3 weeks, SLR sensitivity and specificity decreased as the Modified Bragard test diagnostic accuracy increased. Conclusions The Modified Bragard test is easy to perform and has an acceptable test performance, which can help to increase the discriminative power of clinical examination in patients with L5 or S1 nerve root compression who exhibit a negative SLR test result, especially in the acute phase of disease.
机译:目的本研究的目的是评估对患有L5和S1神经根受压的电诊断患者进行改良Bragard检验与直腿抬高(SLR)检验的诊断准确性。方法这是一项横断面研究,对连续506例经电诊断研究证实具有腰s神经根病症状和体征的患者进行。 2013年9月至2015年9月,在伊朗设拉子的Shahid Faghihi教学医院的物理医学和康复门诊对患者进行了评估。伴随调查了SLR测试以确定敏感性和特异性。结果电诊断研究发现,有312例腰神经根病。在这些参与者中,有198例在SLR测试中呈阳性,在114例SLR阴性患者中,有79例在改良Bragard测试中呈阳性。改良的Bragard试验的灵敏度为69.3%,特异性为67.42%。阳性和阴性预测值分别为73.15%和63.16%。正似然比为2.13,负似然比为0.46。诊断优势比为4.63。症状持续时间少于3周的患者,随着改良Bragard试验诊断准确性的提高,SLR敏感性和特异性下降。结论改良的Bragard试验操作简便,表现令人满意,有助于提高对S5试验阴性的L5或S1神经根受压患者的临床检查的鉴别能力。疾病。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号