首页> 外文期刊>Journal of Dental Sciences >Reliability and accuracy of cone-beam computed tomography voxel density and linear distance measurement at different voxel sizes: A study on sheep head cadaver
【24h】

Reliability and accuracy of cone-beam computed tomography voxel density and linear distance measurement at different voxel sizes: A study on sheep head cadaver

机译:不同体素尺寸的锥束计算机体层摄影体素密度和线性距离测量的可靠性和准确性:绵羊头尸体的研究

获取原文
           

摘要

Background/purpose The reliability and accuracy of linear distance and voxel density (VD) measurements are very important in dentistry. The purpose of this study was to assess the accuracy and reliability of linear distances and VD measurements of cone-beam computed tomography (CBCT) at different voxel sizes. Materials and methods Eighteen-millimeter linears of size 40 gutta-percha were prepared in fresh sheep head. The head was scanned using CBCT with 0.25, 0.3, and 0.40 voxel sizes. Standard linear distances of gutta-percha were measured in panoramic CBCT images at 0.25, 0.3, and 0.4 voxel sizes. VD measurements were made separately on spongeous bone of palatal surfaces of the roots of teeth 4, 5, and 6 of maxilla and on cortical bone of teeth 4, 5, and 6 regions of the left and right hemimandibles through cross-sectional imaging. Results We found that linear distance measurements on panoramic image of CBCT were slightly lower than physical measurements. A significant difference was not found for the gutta-percha linear distances and cortical VD measurements at different voxel sizes (P?≥?0.05). The correlation between measurements of VD at different voxels in cortical bone was greater than 0.85 (P?=?0.000). Conclusion Linear distance measurements on the sheep head cadaver of 0.25, 0.3, and 0.4 voxel sizes were similar and reliable when compared with physical measurements. In minimizing radiation exposure, VD measurement of cortical bone at 0.4 voxel-based CBCT could be used to estimate cortical bone density. However, studies should be performed on the human head cadaver.
机译:背景/目的线性距离和体素密度(VD)测量的可靠性和准确性在牙科中非常重要。这项研究的目的是评估在不同体素尺寸下,锥形束计算机断层扫描(CBCT)的线性距离和VD测量的准确性和可靠性。材料和方法在新鲜绵羊头上制备大小为40 gutta-percha的18毫米线性样品。使用具有0.25、0.3和0.40体素大小的CBCT扫描头部。在0.25、0.3和0.4体素大小的全景CBCT图像中测量了牙胶的标准线性距离。通过横断面成像,分别在上颌牙齿4、5和6的齿根sponge表面的海绵状骨和左侧和右侧下颌骨的牙齿4、5和6区域的皮质骨上分别进行VD测量。结果我们发现CBCT全景图像上的线性距离测量值略低于物理测量值。在不同体素尺寸下,牙胶的线性距离和皮质VD测量值均未发现显着差异(P≥0.05)。皮质骨中不同体素的VD测量值之间的相关性大于0.85(P?=?0.000)。结论在0.25、0.3和0.4体素大小的绵羊头尸体上进行线性距离测量与物理测量相比是相似且可靠的。为了最大程度地减少辐射暴露,可以使用基于0.4体素的CBCT对皮质骨进行VD测量来估计皮质骨密度。但是,应该对人头尸体进行研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号