Optical and Mechanical Clot Detection Methodologies: A Comparison Study for Routine Coagulation Testing

机译:光学和机械凝块检测方法:常规凝血测试的比较研究

获取原文
           

摘要

Automated coagulation analyzers are preferred to meet increasing coagulation test volume. Two distinct technological families exist based on optical and mechanical clot detection methodologies. Which one is superior to the other is still a conflict and needs new studies.MethodsWe have compared prothrombin and activated partial thromboplastin results obtained with mechanical method with those obtained by photo-optical method used routinely in our specialized laboratory.ResultsThe instrumental results showed good precision ranging between 0.7% and 1.8% coefficient of variation. Statistical analysis demonstrated an excellent correlation between the photo-optical and mechanical analyzers for PT (RSUP2/SUP 0.97), and aPTT (RSUP2/SUP 0.85).ConclusionCorrelation between the two clot-detection systems was maintained even when measuring turbid samples (RSUP2/SUP ≥ 0.97 for two tests). J. Clin. Lab. Anal. 26:125-129, 2012. ? 2012 Wiley Periodicals, Inc.
机译:首选自动凝血分析仪来满足不断增加的凝血测试量。基于光学和机械凝块检测方法,存在两种不同的技术系列。方法我们将通过机械方法获得的凝血酶原和活化的部分凝血活酶的结果与在专业实验室中常规使用的光学方法获得的结果进行了比较。结果仪器结果显示出良好的精度变异系数介于0.7%和1.8%之间。统计分析表明,PT(R 2 0.97)和aPTT(R 2 0.85)的光电分析仪与机械分析仪之间具有极好的相关性。结论两个血块之间的相关性甚至在测量混浊样品(两次测试的R 2 ≥0.97)时仍可维持检测系统。 J.临床。实验室肛门26:125-129,2012。 2012 Wiley期刊公司