...
首页> 外文期刊>Journal of Conservative Dentistry >Comparison of efficacy of various root canal irrigation systems in removal of smear layer generated at apical third: An SEM study
【24h】

Comparison of efficacy of various root canal irrigation systems in removal of smear layer generated at apical third: An SEM study

机译:比较各种根管冲洗系统去除根尖处产生的污垢层的功效:SEM研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Aim:The aim of the study is to compare the efficacy of different irrigation systems comparing irrigation with syringe and needle (Dispo Van), Max-I-Probe needle (Dentsply Maillefer), EndoActivator (Dentsply Maillefer), and EndoVac (Sybron Endo) in removing the smear layer generated at apical third.Materials and Methods:Instrumentation was done in 40 extracted premolars using different irrigation regimes (Group 1, saline and syringe; Group 2, Max-I-Probe needles with NaOCl and ethylenediaminetetraacetic acid (EDTA); Group 3, irrigant activation with EndoActivator using needlesNaOCl and EDTA; and Group 4, irrigation with EndoVac using needles NaOCl and EDTA).Statistical Analysis Used:The percentage of debris was seen with scanning electron microscope (SEM) and evaluated using one-way analysis of variance (ANOVA), Kruskal-Wallis test, followed by Mann-Whitney test for significance.Results:The mean score ± standard deviation for the conventional group was 2.8 ± 0.42 with median value of 3.00 (2-3). The results for the Max-I-Probe needle group were 2.3 ± 0.48 with median value of 2.00 (2-3) The mean debris score for EndoActivator group were 0.8 ± 0.42 with median value of 1 (0-1). The mean debris score for EndoVac group were 0.4 ± 0.52 with median value of 1 (0-1).Conclusion:EndoVac and EndoActivator performed much better than other available systems in removing the smear layer from apical third. So they should be incorporated as a regular part of the irrigation regime.
机译:目的:本研究的目的是比较不同灌溉系统的功效,比较使用注射器和针头(Dispo Van),Max-I-Probe针头(Dentsply Maillefer),EndoActivator(Dentsply Maillefer)和EndoVac(Sybron Endo)进行灌溉的效果。材料和方法:使用不同的灌溉方式(第1组,生理盐水和注射器;第2组,带有NaOCl和乙二胺四乙酸(EDTA)的Max-I-Probe针)在40个提取的前磨牙中进行测量。 ;第3组,使用NaOCl和EDTA针使用EndoActivator进行灌溉激活;第4组,使用NaOCl和EDTA针进行EndoVac灌溉。统计分析使用:通过扫描电子显微镜(SEM)观察碎片的百分比,并使用单向评估方差分析(ANOVA),Kruskal-Wallis检验,然后进行Mann-Whitney检验以进行显着性分析。结果:常规组的平均得分±标准差为2.8±0.42,中位数为3。 00(2-3)。 Max-I-Probe针头组的结果为2.3±0.48,中值为2.00(2-3)。EndoActivator组的平均碎片得分为0.8±0.42,中值为1(0-1)。 EndoVac组的平均碎片得分为0.4±0.52,中位数为1(0-1)。结论:EndoVac和EndoActivator在去除根尖上的涂抹层方面比其他可用系统表现更好。因此,应将它们纳入灌溉制度的常规部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号