...
首页> 外文期刊>Journal of Cancer Research and Therapeutics >Conformal electron beam radiotherapy using custom-made step bolus for postmastectomy chest wall irradiation: An institutional experience
【24h】

Conformal electron beam radiotherapy using custom-made step bolus for postmastectomy chest wall irradiation: An institutional experience

机译:使用定制的步进推注进行保形的电子束放射治疗,用于乳房切除术后的胸壁照射:机构经验

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background: Postmastectomy radiation (PMRT) to the chest wall using electron beam treatment with uniform bolus was practiced at our institution. The planning target volume (PTV) included the chest wall and the internal mammary nodes (IMN) along with supraclavicular nodal regions. The varying thickness of the postmastectomy chest wall and the varying position of the IMN resulted in dose inhomogeneity in the PTV. In addition, there was the risk of increased lung and cardiac doses. In this prospective study, we report the making of a custom-made bolus using dental wax called “step bolus.” Materials and Methods: From March 2010 to January 2011, 167 patients received PMRT. As conformal photon plans were not acceptable in 48 patients, they were treated with single energy electrons and custom-made bolus. Results: Addition of the step bolus improved dose distribution to the PTV reduced the mean lung dose %, the mean heart dose % and lung dose (D10, D20, D30, D50, and D70). Forty-seven patients had Grade 2, and one patient had Grade 3 skin toxicity. Acute symptomatic radiation pneumonitis was observed in one patient. At 5 years, 29 patients were alive with a median follow-up of 32 months and no local recurrences were observed. One patient died of myocardial infarction unrelated to treatment, one patient did not come for follow-up, 22 patients had systemic metastases, and 24 patients were disease free. Conclusion: A custom-made step bolus using dental wax can be used for tissue compensation in electron beam therapy with resulting good local disease control and acceptable toxicity.
机译:背景:我们机构实行了采用电子束均匀推注的乳房切除术后对胸壁的放射治疗(PMRT)。规划的目标体积(PTV)包括胸壁和内部乳腺淋巴结(IMN)以及锁骨上淋巴结。乳房切除术后胸壁厚度的变化和IMN位置的变化会导致PTV的剂量不均匀。另外,存在增加肺和心脏剂量的风险。在这项前瞻性研究中,我们报告了使用称为“阶梯式推注”的牙蜡制作的定制推注。材料与方法:从2010年3月至2011年1月,共有167例患者接受了PMRT。由于共形光子计划在48例患者中不可接受,因此用单能电子和定制的推注对它们进行了治疗。结果:在PTV上添加逐步推注可改善剂量分布,从而降低了平均肺部剂量百分比,平均心脏部剂量百分比和肺部剂量(D10,D20,D30,D50和D70)。 47名2级患者和1名3级皮肤毒性患者。一名患者出现了急性症状性放射性肺炎。 5年时,有29名患者还活着,平均随访32个月,未观察到局部复发。 1例患者死于与治疗无关的心肌梗死,1例患者未进行随访,22例患者发生全身转移,24例患者无疾病。结论:使用牙蜡定制的单次推注可用于电子束治疗中的组织补偿,可实现良好的局部疾病控制和可接受的毒性。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号