...
首页> 外文期刊>Journal of Advances in Medical and Pharmaceutical Sciences >Assessment of the Quality of Postero-anterior Chest Radiographs Seen in a North-west Nigerian Tertiary Hospital
【24h】

Assessment of the Quality of Postero-anterior Chest Radiographs Seen in a North-west Nigerian Tertiary Hospital

机译:尼日利亚西北三级医院看后前胸片的质量评估

获取原文
           

摘要

Objectives: To determine the quality of chest radiographs of adult patients x-rayed at Usmanu Danfodiyo University Teaching Hospital (UDUTH) in accordance with Committee of European Commission (CEC) guidelines on quality criteria and to determine the most common factor that affects the radiographs. Materials and Methods: The data was collected retrospectively from the hospital archives using a data capture sheet. Results: A total of 266 radiographs were assessed and the age of patients whose radiographs participated in the study ranged from 20-80years. Also, a greater number of male patients 147(55.3%) participated in the study than female patients 119(44.7%). Results from the study revealed that 194(72.93%) and 225(84.59%) radiographs had correct placement of patient details and anatomical marker respectively. Adequate inspiration was achieved in 223(83.83%) radiographs with presence of artifacts seen in only 17(6.39%) radiographs. Thrown-off scapulae out of lung fields was seen in 174(65.41%) radiographs while adequate penetration was demonstrated in 209(78.57%) radiographs. Fog was seen in 16(6.02%) radiographs and rotation was recorded in 86(32.33%) radiographs. Additionally, blurring and darkroom processing faults affected 9(3.38%) and 42(15.79%) radiographs respectively. The most common cause of poor quality chest radiographs was found to be inadequate collimation affecting 110(41.35%) radiographs. Conclusion: In terms of overall quality, only about 41(15.41%) radiographs met all criteria for a standard chest radiograph according to committee of European commission.
机译:目的:根据欧洲委员会(CEC)关于质量标准的指南,确定在Usmanu Danfodiyo大学教学医院(UDUTH)进行X射线检查的成人患者的胸部X光照片的质量,并确定影响X光照片的最常见因素。材料和方法:数据是使用数据采集表回顾性地从医院档案中收集的。结果:总共评估了266张射线照相,参加该研究的射线照相患者的年龄为20-80岁。此外,参与研究的男性患者147(55.3%)比女性患者119(44.7%)更多。研究结果显示,分别有194张(72.93%)和225张(84.59%)的X射线照片分别正确放置了患者详细信息和解剖标记。在223张(83.83%)的X射线照片中获得了足够的灵感,只有17张(6.39%)的X射线照片中出现了伪影。在174张(65.41%)的X射线照片中可见被甩出的肩cap骨,而在209张(78.57%)的X射线照片中证实有足够的穿透力。在16幅X射线照片中见到雾气,在86幅X射线照片中记录到旋转。此外,模糊和暗室处理故障分别影响了9张(3.38%)和42张(15.79%)X射线照片。发现胸片质量较差的最常见原因是准直度不足,影响了110片(41.35%)。结论:就整体质量而言,根据欧洲委员会的委员会,仅约41例(15.41%)的X线照片符合标准胸片的所有标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号