Context Functional performance tests (FPTs) are tools used to assess dynamic muscle strength and power. In contrast to the lower extremity, fewer FPTs are available for the upper extremity. The seated single-arm shot put test has the potential to fill the void in upper extremity FPTs; however, the underlying mechanics have not been examined and, therefore, the validity of bilateral comparisons is unknown. Objective To examine the effects of upper extremity dominance and medicine-ball mass on the underlying mechanics of the seated single-arm shot put. Design Crossover study. Setting Biomechanics laboratory. Patients or Other Participants Fifteen women (age = 23.6 ± 2.1 years, height = 1.65 ± .07 m, mass = 68.1 ± 11.7 kg) and 15 men (age = 24.3 ± 4.0 years, height = 1.80 ± 0.06 m, mass = 88.1 ± 16.4 kg), all healthy and physically active. Intervention(s) Seated single-arm shot-put trials using the dominant and nondominant limbs were completed using three 0.114-m-diameter medicine-ball loads (1 kg, 2 kg, 3 kg). Main Outcome Measure(s) Customized touch-sensitive gloves, synchronized with kinematic data of the hands, signaled ball release, so that release height, release angle, and peak anterior and vertical velocity could be quantified for each trial. In addition, the horizontal range from release to first floor impact was recorded. Results The dominant-limb horizontal ranges were 7% to 11% greater (P .001) than for the nondominant limb for each of the 3 ball masses. No bilateral release-height or -angle differences were revealed (P ≥ .063). Release velocities were 7.6% greater for the dominant limb than the nondominant limb (P = .001). Conclusions Our results support the use of the seated single-arm shot put test as a way to compare bilateral upper extremity functional performance. The near-identical release heights and angles between the dominant and nondominant limbs support the interpretation of measured bilateral horizontal-range differences as reflecting underlying strength and power differences.
机译:功能功能测试(FPT)是用于评估动态肌肉力量和力量的工具。与下肢相反,上肢可用的FPT较少。坐姿单臂铅球测试有可能填补上肢FPT中的空白;但是,尚未对基本机制进行检查,因此,双边比较的有效性尚不清楚。目的探讨上肢优势和药球质量对坐式单臂铅球的基础力学的影响。设计跨界研究。设置生物力学实验室。患者或其他参与者15名女性(年龄= 23.6±2.1岁,身高= 1.65±.07 m,体重= 68.1±11.7 kg)和15名男性(年龄= 24.3±4.0岁,身高= 1.80±0.06 m,质量= 88.1) ±16.4公斤),所有身体健康且活跃。干预通过使用三个直径为0.114米的药球负荷(1公斤,2公斤,3公斤),完成了使用优势和非优势四肢的坐姿单臂射击试验。主要成果测量指标定制的触敏手套,与手的运动学数据同步,发出球释放的信号,以便可以为每个试验量化释放高度,释放角度以及峰值前后速度。另外,记录了从释放到第一层撞击的水平范围。结果3个球团中的每个球的优势肢水平范围比非优势肢大7%至11%(P <.001)。未发现双侧释放高度或角度差异(P≥.063)。优势肢的释放速度比非优势肢高7.6%(P = .001)。结论我们的结果支持使用坐式单臂铅球测试作为比较双侧上肢功能性能的一种方法。优势肢和非优势肢之间几乎相同的释放高度和角度支持解释测量到的双侧水平距离差异,以反映潜在的力量和力量差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号