A new transmission methodology for quality assurance in radiotherapy based on radiochromic film measurements

机译:基于放射变色胶片测量的放射治疗质量保证的新传输方法

获取原文
           

摘要

Despite individual quality assurance (QA) being recommended for complex techniques in radiotherapy (RT) treatment, the possibility of errors in dose delivery during therapeutic application has been verified. Therefore, it is fundamentally important to conduct in vivo QA during treatment. This work presents an in vivo transmission quality control methodology, using radiochromic film (RCF) coupled to the linear accelerator (linac) accessory holder. This QA methodology compares the dose distribution measured by the film in the linac accessory holder with the dose distribution expected by the treatment planning software. The calculated dose distribution is obtained in the coronal and central plane of a phantom with the same dimensions of the acrylic support used for positioning the film but in a source-to-detector distance (SDD) of 100 cm, as a result of transferring the IMRT plan in question with all the fields positioned with the gantry vertically, that is, perpendicular to the phantom. To validate this procedure, first of all a Monte Carlo simulation using PENELOPE code was done to evaluate the differences between the dose distributions measured by the film in a SDD of 56.8 cm and 100 cm. After that, several simple dose distribution tests were evaluated using the proposed methodology, and finally a study using IMRT treatments was done. In the Monte Carlo simulation, the mean percentage of points approved in the gamma function comparing the dose distribution acquired in the two SDDs were 99.92 % ± 0.14 % . In the simple dose distribution tests, the mean percentage of points approved in the gamma function were 99.85 % ± 0.26 % and the mean percentage differences in the normalization point doses were ? 1.41 % . The transmission methodology was approved in 24 of 25 IMRT test irradiations. Based on these results, it can be concluded that the proposed methodology using RCFs can be applied for in vivo QA in RT treatments.PACS number: 87.55.Qr, 87.55.km, 87.55.N-
机译:尽管建议对放射治疗(RT)治疗中的复杂技术建议使用个人质量保证(QA),但已经证实了在治疗应用过程中剂量输送有错误的可能性。因此,在治疗期间进行体内质量检查至关重要。这项工作提出了一种体内透射质量控制方法,该方法使用了与线性加速器(直线加速器)附件支架耦合的放射致变色膜(RCF)。此QA方法将直线加速器附件支架中的薄膜测量的剂量分布与治疗计划软件预期的剂量分布进行了比较。计算出的剂量分布是在幻影的冠状和中心平面内获得的,该幻影具有与用于放置胶片的丙烯酸载体相同的尺寸,但在源与检测器之间的距离(SDD)为100厘米,这是由于转移了IMRT计划中的所有字段都垂直放置在机架上,即垂直于模型。为了验证该程序,首先使用PENELOPE代码进行了蒙特卡罗模拟,以评估在56.8 cm和100 cm的SDD中薄膜测量的剂量分布之间的差异。之后,使用提出的方法评估了几个简单的剂量分布测试,最后进行了使用IMRT治疗的研究。在蒙特卡洛模拟中,比较两个SDD中获得的剂量分布的伽马函数中批准的点的平均百分比为99.92%±0.14%。在简单的剂量分布测试中,γ功能中批准的平均分数百分比为99.85%±0.26%,归一化剂量的平均百分比差异为。 1.41%。该传输方法已在25次IMRT测试辐射中的24次中得到批准。基于这些结果,可以得出结论,所提出的使用RCF的方法可以应用于RT治疗中的体内QA.PACS编号:87.55.Qr,87.55.km,87.55.N-

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号