A novel IMRT phantom was designed and fabricated using Acrylonitrile Butadiene Styrene (ABS) plastic. Physical properties of ABS plastic related to radiation interaction and dosimetry were compared with commonly available phantom materials for dose measurements in radiotherapy. The ABS IMRT phantom has provisions to hold various types of detectors such as ion chambers, radiographic/radiochromic films, TLDs, MOSFETs, and gel dosimeters. The measurements related to pretreatment dose verification in IMRT of carcinoma prostate were carried out using ABS and Scanditronix‐Wellhofer RW3 IMRT phantoms for five different cases. Point dose data were acquired using ionization chamber and TLD discs, while Gafchromic EBT and radiographic EDR2 films were used for generating 2D dose distributions. Treatment planning system (TPS) calculated and measured doses in ABS plastic and RW3 IMRT phantom were in agreement within . The dose values at a point in a given patient acquired using ABS and RW3 phantoms were found comparable within 1%. Fluence maps and dose distributions of these patients generated by TPS and measured in ABS IMRT phantom were also found comparable both numerically and spatially. This study indicates that ABS plastic IMRT phantom is a tissue‐equivalent phantom and, dosimetrically, it is similar to solid/plastic water IMRT phantoms. Although this material is demonstrated for IMRT dose verification, it can also be used as a tissue‐equivalent phantom material for other dosimetry purposes in radiotherapy. PACS number: 87.53Kn, 87.55Qr, 87.53Bn and 87.55Km
机译:使用丙烯腈丁二烯苯乙烯(ABS)塑料设计和制造了新型IMRT体模。将与放射相互作用和剂量测定有关的ABS塑料的物理特性与常用的幻象材料进行了比较,以进行放射治疗中的剂量测量。 ABS IMRT体模可容纳各种类型的检测器,例如离子室,射线照相/放射变色膜,TLD,MOSFET和凝胶剂量计。针对五种不同情况,使用ABS和Scanditronix-Wellhofer RW3 IMRT体模进行了与前列腺癌IMRT中的预处理剂量验证相关的测量。使用电离室和TLD光盘获取点剂量数据,而Gafchromic EBT和X射线EDR2胶片用于生成2D剂量分布。在ABS塑料和RW3 IMRT体模中,治疗计划系统(TPS)计算和测量的剂量一致。发现使用ABS和RW3体模在给定患者中某点的剂量值可比在1%之内。还发现,通过TPS生成并在ABS IMRT体模中测量的这些患者的通量图和剂量分布在数值和空间上均具有可比性。这项研究表明,ABS塑料IMRT体模是一种组织等效体模,从剂量学上讲,它类似于固体/塑料水IMRT体模。尽管已证明该材料可用于IMRT剂量验证,但它也可用作组织等效的体模材料,用于放射治疗中的其他剂量测定目的。 PACS编号:87.53Kn,87.55Qr,87.53Bn和87.55Km

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号