首页> 外文期刊>Journal of Analytical & Bioanalytical Techniques >A Highly Sensitive Method for the Quantitation of Polysorbate 20 and 80 to Study the Compatibility between Polysorbates and m-Cresol in the Peptide Formulation
【24h】

A Highly Sensitive Method for the Quantitation of Polysorbate 20 and 80 to Study the Compatibility between Polysorbates and m-Cresol in the Peptide Formulation

机译:定量测定山梨酯20和80的高灵敏度方法,以研究肽配方中山梨酸酯和间甲酚之间的相容性

获取原文

摘要

A highly sensitive method has been developed for the quantitation of polysorbate 20 (PS20) and 80 (PS80) in therapeutic peptide formulations. A mixed-mode HPLC column was used to separate polysorbates from the peptide and other excipients, and a charged aerosol detector (CAD) was used for the detection. The method was capable of reporting polysorbates as low as 5 ppm, and the sensitivity could be further improved on a needed basis. The method has been used to study the compatibility between polysorbates and m-cresol in the peptide formulation. It was found that both PS20 and PS80 are compatible with m-cresol (at 2.8 mg/ml) when their levels were not greater than 20 ppm. Significant losses of polysorbates were observed when PS20 and PS80 concentrations were above 50 ppm. Furthermore, the agitation study demonstrated that even trace levels of PS20 and PS80 (e.g., 20 ppm) could stabilize the peptide against fibrillation and aggregation.
机译:已开发出一种高度灵敏的方法,用于定量治疗性肽制剂中的聚山梨酯20(PS20)和80(PS80)。使用混合模式HPLC色谱柱从肽和其他赋形剂中分离聚山梨酸酯,并使用带电气溶胶检测器(CAD)进行检测。该方法能够报告低至5 ppm的聚山梨酯,并且可以根据需要进一步提高灵敏度。该方法已用于研究肽配方中聚山梨酯和间甲酚之间的相容性。发现当它们的含量不大于20ppm时,PS20和PS80都与间甲酚(2.8mg / ml)相容。当PS20和PS80浓度高于50 ppm时,观察到聚山梨酯的大量损失。此外,搅动研究表明,即使痕量的PS20和PS80(例如20ppm)也可以稳定该肽抵抗原纤维形成和聚集。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号