Thirty-one normal subjects and 16 subjects with documented myocardial infarction were studied. The Frank system of vectorcardiography was used. The polar vector and 0.04 polar vector were calculated in all. The 0.04 polar vector was abnormally directed in all cases of documented infarction, including 2 subjects with a documented infarction but a "suggestive" electrocardiogram. The results of this preliminary study suggest that this method of vectorcardiographic analysis may be of a clinical value in those cases with a previous myocardial infarction in which the present electrocardiogram is suggestive but not diagnostic of an infarction. The results also demonstrate the greater diagnostic value of the 0.04 polar vector over the polar vector in detecting myocardial infarction.
机译:研究对象为31名正常人和16名有心肌梗死记录的人。使用矢量心动图的Frank系统。总共计算了极向量和0.04极向量。在所有有记录的梗塞病例中,0.04极性向量均被异常定向,包括2名有记录的梗塞但“建议性”心电图的受试者。这项初步研究的结果表明,这种矢量心电图分析方法在先前有心肌梗塞的病例中可能具有临床价值,在这些病例中,本心电图可提示但不能诊断出梗死。结果还证明,在检测心肌梗塞中,0.04极性载体比极性载体具有更大的诊断价值。