A 74-year-old man with a preoperative manifest refraction of ?3.00 +1.00 × 25 had cataract extraction and implantation of a toric intraocular lens (IOL). Although the IOL power was chosen according to the surgical records and accurately aligned on the target axis at the follow-up examination, the incision apparently induced enough surgically induced astigmatism (SIA) to make the cornea spherical. The patient was dissatisfied with the resulting flipped axis and 20/60 uncorrected acuity. Intraoperative aberrometry confirmed that the cornea was now spherical. An IOL exchange was performed with placement of a 22.0 diopter nontoric IOL. The second surgery was complicated by early capsule phimosis. Because it can measure true aphakic corneal astigmatism intraoperatively, intraoperative aberrometry can be useful in preventing IOL exchanges due to anomalous SIA. Financial Disclosure The author has no financial or proprietary interest in any material or method mentioned.
机译:一名术前屈光度≥3.00+1.00×25的74岁男子进行了白内障摘除并植入了复曲面人工晶状体(IOL)。尽管根据手术记录选择了人工晶状体屈光力,并在随访检查中将其准确对准目标轴,但切口显然引起了足够的手术诱发散光(SIA),使角膜呈球形。患者对由此产生的轴翻转和20/60矫正视力不满意。术中像差法证实角膜现在是球形的。通过放置22.0屈光度非扭转性IOL进行IOL交换。第二次手术因早期包膜包茎而并发。因为它可以在术中测量真正的无晶状体角膜散光,所以术中像差法可用于预防由于SIA异常引起的IOL交换。财务披露作者对所提及的任何材料或方法均无财务或所有权利益。