首页> 外文期刊>Dental Press Journal of Orthodontics >Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs
【24h】

Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs

机译:常规和CBCT重建全景X射线照片的齿长测量精度和可靠性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

INTRODUCTION: This in vivo study assessed accuracy and reliability of tooth length measurements obtained from conventional panoramic radiographs and CBCT panoramic reconstructions to that of a digital caliper (gold standard). METHODS: The sample consisted of subjects who had CBCT and conventional panoramic radiographic imaging and who required maxillary premolar extraction for routine orthodontic treatment. A total of 48 teeth extracted from 26 subjects were measured directly with digital calipers. Radiographic images were scanned and digitally measured in Dolphin 3D software. Accuracy of tooth length measurements made by CBCT panoramic reconstructions, conventional panoramic radiographs and digital caliper (gold standard) were compared to each other by repeated measures one-way ANOVA with Bonferroni correction and by single measures intraclass correlation coefficient. RESULTS: Repeated root length measures with digital calipers, panoramic radiographs and CBCT constructed panoramic-like images were all individually highly reliable. Compared to the caliper (gold standard), tooth measurements obtained from conventional panoramic radiographs were on average 6.3 mm (SD = 2.0 mm) longer, while tooth measurements from CBCT panoramic reconstructions were an average of 1.7 mm (SD = 1.2 mm) shorter. CONCLUSIONS: In comparison to actual tooth lengths, conventional panoramic radiographs were relatively inaccurate, overestimating the lengths by 29%, while CBCT panoramic reconstructions underestimated the lengths by 4%.
机译:简介:这项体内研究评估了从常规全景X射线照片和CBCT全景重建到数字卡尺(黄金标准)的牙齿长度测量的准确性和可靠性。方法:样本由具有CBCT和常规全景X线摄影术且需要常规常规正畸治疗的上颌前磨牙摘除术的受试者组成。使用数字卡尺直接测量了从26位受试者中提取的总共48条牙齿。在Dolphin 3D软件中扫描放射线图像并进行数字测量。通过CBCT全景重建,常规全景X射线照片和数字卡尺(金标准)进行的牙齿长度测量的准确性,通过采用Bonferroni校正的单向ANOVA重复测量和同级内相关系数的单次测量相互比较。结果:用数字卡尺,全景射线照相和CBCT构造的全景样图像反复进行根长测量,均具有很高的可靠性。与卡尺(金标准)相比,从常规全景X射线照片获得的牙齿测量结果平均要长6.3毫米(SD = 2.0毫米),而从CBCT全景重建得到的牙齿测量结果平均要短1.7毫米(SD = 1.2毫米)。结论:与实际的牙齿长度相比,常规的全景X线照片相对不准确,高估了29%,而CBCT全景重建低估了4%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号