Ultra-high-voltage (UHV) transmission lines have a higher requirement for selecting faulted phases fast and reliably. The coupling relationship between the three phases is analysed in detail. On the basis of the coupling relationship, the principle of faulted phase selection (FPS) is proposed, which utilises the time-domain energy of three-phase transient currents. To remove high-frequency noise and preserve the transient current waveform features invariant, a morphological filter with flat structure element is applied in FPS algorithm. The simulation model of Jindongnana??Nanyanga??Jingmen UHV transmission project is established in EMTP. The testing results show that the proposed algorithm is feasible and fast (&2a??ms) in case of various fault conditions.
机译:超高压(UHV)输电线路具有对快速可靠地选择故障相的更高要求。详细分析了三相之间的耦合关系。在耦合关系的基础上,提出了利用三相暂态电流时域能量的故障选相原理。为了消除高频噪声并保持瞬态电流波形特征不变,在FPS算法中应用了具有扁平结构元素的形态滤波器。在EMTP中建立了金东纳那—南阳加—荆门特高压输电工程的仿真模型。测试结果表明,所提出的算法在各种故障条件下都是可行且快速的(<2aΔms)。