Forced Coag, effect 2, 80 W; Erbe Elektromedizin GmbH, Tuebingen, Germany). Four tiny ports at the tip of the sheath can both suck and inject liquid; to use suction, the assistant manually applies negative pressure to the distal end of the sheath using a syringe. This function maintains visibility at the operation site while sucking up bloody fluid, enabling the endoscopist to recognize the bleeding point and perform precise hemostasis (Figs. 1-6). Furthermore, in comparison with conventional needle-type knives, the ball-shaped tip is slightly thicker in diameter, possibly leading to a higher hemostatic ability against submucosal blood vessels.
机译:强制凝块,效果2,80 W; Erbe Elektromedizin GmbH,德国图宾根)。护套尖端的四个细小端口既可以吸入液体,也可以注入液体。为了使用吸力,助手使用注射器将负压手动施加到护套的远端。该功能可在吸取带血液体的同时保持手术部位的可见性,使内镜医师能够识别出血点并精确止血(图1-6)。此外,与常规的针型刀相比,球形尖端的直径稍厚,可能导致更高的针对粘膜下血管的止血能力。