In this paper, a dynamic model is developed for high-voltage circuit breakers to extract fault features and causes. Lagrange's method is applied using geometric equations of mechanism components to write the model. Unlike previous approaches, the proposed method reveals and analyzes all types of circuit breaker operating mechanism faults. Early fault detection, which is a vital requirement of the fault diagnosis system, becomes feasible by keeping track of changes in the contact travel curve in the proposed model. Resulting faults in the travel curve are analyzed mathematically in order to find out the exact origin of the fault. Field test results show the accuracy and reliability of the fault detection method.
机译:本文针对高压断路器建立了动态​​模型,以提取故障特征和原因。拉格朗日的方法是使用机械零件的几何方程式编写模型的。与以前的方法不同,该方法揭示并分析了所有类型的断路器操作机构故障。通过跟踪所提出模型中接触行程曲线的变化,早期故障检测是故障诊断系统的重要要求,因此变得可行。对行进曲线中产生的故障进行数学分析,以找出故障的确切来源。现场测试结果表明了该故障检测方法的准确性和可靠性。