...
首页> 外文期刊>Turkish journal of chemistry >Voltammetric determination of phenmedipham herbicide using a multiwalled carbon nanotube paste electrode
【24h】

Voltammetric determination of phenmedipham herbicide using a multiwalled carbon nanotube paste electrode

机译:使用多壁碳纳米管糊状电极伏安法测定苯甲地平除草剂

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Phenmedipham is an herbicide used especially in the sugar beet harvest to fight against broad-leaved weeds and studies of its voltammetric behavior and detection have not been done before. The superior properties of carbon nanotubes such as electrical conductivity, mechanical strength, and wide potential ranges make them attractive for chemical sensors and the phenmedipham compound gave an oxidation peak at $+$1320 mV (vs. Ag/AgCl) on the nanostructured multiwalled carbon nanotube paste electrode. Square wave voltammetric measurements recorded for phenmedipham showed that the peak current increased linearly between 0.02 and 2.0 mg/L with a regression coefficient of $r$ = 0.9989, and the limit of detection and limit of quantification were calculated as 6.96 $mu $g/L and 23.2 $mu $g/L, respectively. The applicability and the selectivity of the improved square wave voltammetric method for the phenmedipham assay were investigated in the presence of certain herbicides and fungicides such as carbendazim, benomyl, aclonifen, ethofumesate, metamitron, and p-acetanisidide (methacetin). Phenmedipham at 1 mg/L with the same amount of these pesticides was determined to have recoveries of 103.5 $pm $ 0.7, 94.5 $pm $ 2.8, 104.3 $pm $ 1.8, 101.9 $pm $ 3.1, 93.8 $pm $ 1.7, and 101.3 $pm $ 1.8, respectively (n = 3). The method was also applied to the phenmedipham assay in saturated tea sugar prepared as a spiked natural sample and 1.0 g/L phenmedipham in the sugar solution was successfully determined with a relative error of --5.0% and a relative standard deviation of 3.16%.
机译:苯甲双胍是一种除草剂,特别用于甜菜收获中以对抗阔叶杂草,并且以前尚未进行过伏安法行为和检测的研究。碳纳米管的优越性能,如电导率,机械强度和宽电位范围,使其对化学传感器具有吸引力,而苯乙二胺化合物在纳米结构多壁碳纳米管上的氧化峰位于$ + $ 1320 mV(相对于Ag / AgCl)。粘贴电极。记录苯甲地平的方波伏安法测量结果表明,峰值电流在0.02和2.0 mg / L之间线性增加,回归系数为$ r $ = 0.9989,计算出的检出限和定量限为6.96 $ mu $ g / L和23.2 $ mu $ g / L。在某些除草剂和杀真菌剂(例如多菌灵,苯菌灵,阿克洛芬,乙草铵,metamitron和对乙酰胺(美沙西丁))存在下,研究了改进的方波伏安法在苯甲地平分析中的适用性和选择性。以1 mg / L浓度的苯丙胺定和这些农药的相同含量测定的回收率分别为103.5 $ pm $ 0.7、94.5 $ pm $ 2.8、104.3 $ pm $ 1.8、101.9 $ pm $ 3.1、93.8 $ pm $ 1.7和101.3 $ pm $ 1.8(n = 3)。该方法还适用于以加标天然样品形式制备的饱和茶糖中的苯甲地平测定,并成功测定了糖溶液中1.0 g / L苯甲地平,相对误差为--5.0%,相对标准偏差为3.16%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号