首页> 外文期刊>Thermal science >Analysis of operation of the condenser in a 120 MW thermal power plant
【24h】

Analysis of operation of the condenser in a 120 MW thermal power plant

机译:120 MW火力发电厂冷凝器的运行分析

获取原文

摘要

The condenser plant has a huge impact on the economy of a steam turbine power plant. Deterioration of the parameters during operation could lead to a significant decrease in electrical output and to an increase in the heat rate of the thermal power plant. Detailed calculations of the performance under different operating conditions were carried out for the condenser of the Morava thermal power plant. Comprehensive testing of the condenser was carried out and experimental data were compared with the numerical results. The effects of deviations in the condenser behaviour on the main thermodynamic parameters and the overall economics of the power plant were evaluated. Guidelines for operation of condensation plants are given in the conclusion.
机译:冷凝器工厂对蒸汽轮机发电厂的经济影响巨大。在运行期间参数的恶化可能导致电力输出的显着下降以及火力发电厂的热效率的上升。对Morava热电厂的冷凝器在不同运行条件下的性能进行了详细的计算。对冷凝器进行了综合测试,并将实验数据与数值结果进行了比较。评估了冷凝器性能偏差对主要热力学参数和电厂整体经济性的影响。结论中给出了冷凝装置的操作指南。