In the V?g? study of headache epidemiology, the “skinrolltest” was carried out at the top (“arch”) of the shouldergirdle. For this purpose, a skin caliper (Servier, Leiden) wasused. A total of 1796 parishioners aged 18–65 years (51% women)was examined. A repeat test was also carried out. The skin-rolltest consists of two components: measurement of skin-foldthickness and assessment of the pain level. The average archskinfold thickness on the right side, was 15.0 (SD=5.9 mm;range, 3–60) and was significantly lower in men (mean, 13.8 mm)than in women (16.1 mm). Among the subjects without headache(n=246), the average skin-fold thickness was 14.3 (SD=5.7 mm).Immediately repeating the test revealed a measurement error>3 mm in 1.1% of cases. Asymmetry in the shoulder arch areaexceeded the measurement error in 6.1% of the cases. Theskin-fold thickness at an anterior site in the shoulder area wasalways less than that at the shoulder arch.
机译:在V?g?在研究头痛流行病学时,“ skinrolltest”是在肩带的顶部(“拱”)进行的。为此,使用了皮肤卡尺(Servier,Leiden)。共检查了1796名18-65岁的教区居民(女性占51%)。还进行了重复测试。皮肤滚动测试包括两个部分:皮肤折叠厚度的测量和疼痛程度的评估。右侧的平均足弓皮厚度为15.0(SD = 5.9毫米;范围3-60),男性(平均13.8毫米)明显低于女性(16.1毫米)。在没有头痛的受试者中(n = 246),平均皮肤折叠厚度为14.3(SD = 5.7mm)。立即重复测试发现在1.1%的病例中测量误差大于3mm。在6.1%的病例中,肩弓区域的不对称性超出了测量误差。肩部前部部位的皮褶厚度始终小于肩the骨处的皮褶厚度。