首页> 外文期刊>The Internet Journal of Plastic Surgery >Reducing Anastomotic Time - Technical Aspects Of Using The VCS? Clip Applier For Microvascular Anastomosis In Free Flap Surgery.
【24h】

Reducing Anastomotic Time - Technical Aspects Of Using The VCS? Clip Applier For Microvascular Anastomosis In Free Flap Surgery.

机译:减少吻合时间-使用VCS的技术方面?自由瓣手术中用于微血管吻合的夹子钳。

获取原文
       

摘要

Technical aspects of using the VCS(r) clip applier (a nonpenetrating titanium clip applied in an interrupted, everting fashion) for microvascular anastomoses are discussed. This technique has the advantage that it can be used for arterial, venous, end-to-side, and end-to-end anastomoses. It is a fast, reliable technique, with a very low complication rate, which can reduce total anastomotic time to 10-20 minutes. This technique has definite advantages in complex or lengthy reconstructions eg where 2 free flaps are being performed, where vein grafts are being used, or where access to the anastomosis is limited. INTRODUCTION Free flaps have now become a routine part of reconstructive surgery practice. Although failure rates have decreased with increasing experience, there is still a significant failure rate, even in the best hands. Many free flap failures are due to technical problems in performing the anastomosis. To try to reduce the complication rate there have been many alternatives developed to sutured anastomoses, including cuffs/couplers, penetrating staples, adhesives, and laser welding.1,2,3,4,5,6,7,8. Although many of these anastomotic devices have been available for many years, none has gained widespread acceptance. The most popular of these, the 3M precise microanastomotic vascular system has been available for 10 years, with 2 clinical studies showing the effectiveness of this system 9,10. The VCS(r) clip applier (a nonpenetrating titanium clip applied in an interrupted, everting fashion) was first reported in 199211, and has recently been shown to be an effective method of performing microvascular anastomoses in a large clinical series12. This technique has a number of advantages over other non-suture methods. Not only can it significantly reduce the anastomotic time, but it also has a very low complication rate. In this report we give details, including potential pitfalls, of the technique. TECHNIQUE The VCS(r) (vascular closure staple) clip is an arcuate-legged, nonpenetrating titanium clip manufactured by Autosuture. It is available in 3 sizes (see below), 2 of which are applicable to microsurgery – the small (0.9mm) and medium (1.4mm) sizes. The larger size is only applicable for macrovascular anastomoses.
机译:讨论了使用VCS(r)夹钳(一种非穿透性的钛夹,以间断的,外翻的方式施加)进行微血管吻合的技术方面。该技术的优点是可以用于动脉,静脉,端对端和端对端吻合。这是一种快速,可靠的技术,并发症发生率非常低,可以将总吻合时间减少到10-20分钟。该技术在复杂或冗长的重建中具有明显的优势,例如在执行2个游离皮瓣,使用静脉移植物或限制吻合的地方。引言现在,游离皮瓣已成为重建外科手术的常规部分。尽管故障率随着经验的增加而降低,但是即使在最佳的情况下,故障率仍然很高。许多游离瓣失败是由于进行吻合术中的技术问题引起的。为了降低并发症的发生率,缝合吻合口有很多替代方法,包括袖套/连接器,钉书钉,粘合剂和激光焊接[1,2,3,4,5,6,7,8]。尽管这些吻合装置中的许多已经使用了很多年,但是没有一个被广泛接受。其中最受欢迎的是3M精密微解剖血管系统,已有10年的历史,两项临床研究表明该系统的有效性9,10。 VCS(r)夹钳(一种非穿透性的钛夹,以间断的,外翻的方式施加)于199211年首次报道,最近被证明是在大型临床系列中进行微血管吻合的一种有效方法。与其他非缝合方法相比,该技术具有许多优点。它不仅可以大大减少吻合时间,而且并发症发生率也非常低。在此报告中,我们提供了该技术的详细信息,包括潜在的陷阱。技术VCS(r)(血管闭合吻合钉)夹子是由Autosuture生产的弓形腿,非穿透性钛夹子。它有3种尺寸(见下文),其中2种适用于显微外科手术-小(0.9mm)和中(1.4mm)尺寸。较大的尺寸仅适用于大血管吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号