This work has compared the surfaces of two different steel samples used as orthopedical implants, classified as ASTM F138 and ISO5832-9, through optical emission spectroscopy, by means of SEM and EDS. The samples (implants) were also submitted to potentiodynamic cyclic polarization in Ringer lactate and NaCl 0.9 M L-1 solutions; ISO5832-9 sample did not show any kind of localized corrosion, but in the case of F138 steel was observed a pit localized corrosion in both solutions. In Ringer lactate solution it was observed a loss of about 63% for nickel and 26% for iron for F138 stell, compared to the initial composition.
机译:这项工作通过SEM和EDS通过光发射光谱法比较了用作矫形植入物的两种不同钢样品的表面,分别分类为ASTM F138和ISO5832-9。样品(植入物)也要在乳酸林格氏液和NaCl 0.9 M L-1溶液中进行电位动力学循环极化。 ISO5832-9样品未显示任何类型的局部腐蚀,但在F138钢的情况下,在两种溶液中均观察到了凹坑局部腐蚀。在乳酸林格氏液中,与初始成分相比,F138的镍损失约63%,铁损失约26%。