首页> 外文期刊>Pró-Fono Produtos Especializados para Fonoaudiologia Ltda: Pro-Fono R. Atual. Cient >Reliability of an instrument to assess the readiness of preterm infants for oral feeding
【24h】

Reliability of an instrument to assess the readiness of preterm infants for oral feeding

机译:评估早产儿口服喂养准备情况的仪器的可靠性

获取原文
           

摘要

BACKGROND: the transition from gastric to oral feeding of preterm infants is one of the greatest concerns of health professionals and therefore needs an objective criterion to support the beginning of this process. AIM: to test the reliability of an instrument that assesses the readiness of preterm infants for the transition from gastric to oral feeding. METHOD: the instrument is composed by the following items: corrected gestational age; behavioral state; global posture and tonus; lips and tongue posture; rooting, suck, bite and gag reflexes; tongue and jaw movements; tongue cupping; sucking strain; sucking and pause; maintenance sucking/pause; maintenance alert state and stress signs. The study was conducted at the Intermediate Care Unit of the Hospital de Clínicas da Faculdade de Medicina de Ribeir?o Preto - University of S?o Paulo. The research sample consisted of 30 preterm infants who attended the following inclusion criteria: corrected gestational age <36 weeks and 6 days; clinically stable; absence of facial deformities; respiratory, cardiovascular, gastrointestinal and neurological disorders or syndromes that prevent or make oral feeding difficu and not having received oral feeding of milk. The Kappa Test was used to verify interjudge reliability. RESULTS: the items that presented high reliability levels were: behavioral state, global posture and tonus, lips and tongue posture, gag reflex and maintenance of alert state. The items that presented satisfactory reliability levels were: rooting reflex, sucking and biting and jaw movement, sucking strain and sucking and pause. Only the items of tongue cupping, maintenance of sucking/pause and stress signs presented unsatisfactory reliability levels. CONCLUSION: in general, the items investigated by the assessment instrument presented adequate interjudge reliability.
机译:背景:早产儿从胃喂养过渡到口服喂养是卫生专业人员最关心的问题之一,因此需要一个客观的标准来支持这一过程的开始。目的:测试一种评估早产儿从胃喂养到口服喂养准备情况的仪器的可靠性。方法:该仪器由以下几部分组成:校正的胎龄;行为状态全球姿势和紧张感;嘴唇和舌头的姿势;生根,吮吸,咬咬和呕吐反射;舌头和颌骨运动;舌头拔火罐吸力吮吸和停顿;维持吮吸/暂停;维护警报状态和压力迹象。这项研究是在里贝里奥·普雷托-圣保罗大学医学院附属医院的中级监护室进行的。该研究样本由30名符合以下纳入标准的早产儿组成:校正的胎龄<36周零6天;临床稳定;没有面部畸形;阻止或使口服喂养困难的呼吸道,心血管,胃肠道和神经系统疾病或综合征;而且还没有口服牛奶。 Kappa测试用于验证裁判间的可靠性。结果:具有较高可靠性的项目为:行为状态,整体姿势和趾高,嘴唇和舌头姿势,堵嘴反射和保持警觉状态。表现出令人满意的可靠性水平的项目是:生根反射,吮吸和咬伤以及下巴运动,吮吸劳损以及吮吸和暂停。仅舌头拔罐,保持吮吸/暂停和压力征象等项目的可靠性水平不令人满意。结论:总体而言,评估工具所调查的项目具有足够的法官间信度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号