首页> 外文期刊>Sports >Using Unilateral Strength, Power and Reactive Strength Tests to Detect the Magnitude and Direction of Asymmetry: A Test-Retest Design
【24h】

Using Unilateral Strength, Power and Reactive Strength Tests to Detect the Magnitude and Direction of Asymmetry: A Test-Retest Design

机译:使用单边强度,功率和无功强度测试来检测不对称的幅度和方向:重新测试设计

获取原文
           

摘要

The aims of the present study were to determine test-retest reliability for unilateral strength and power tests used to quantify asymmetry and determine the consistency of both the magnitude and direction of asymmetry between test sessions. Twenty-eight recreational trained sport athletes performed unilateral isometric squat, countermovement jump (CMJ) and drop jump (DJ) tests over two test sessions. Inter-limb asymmetry was calculated from both the best trial and as an average of three trials for each test. Test reliability was computed using the intraclass correlation coefficient (ICC), coefficient of variation (CV) and standard error of measurement (SEM). In addition, paired samples t -tests were used to determine systematic bias between test sessions and Kappa coefficients to report how consistently asymmetry favoured the same side. Within and between-session reliability ranged from moderate to excellent (ICC range = 0.70–0.96) and CV values ranged from 3.7–13.7% across tests. Significant differences in asymmetry between test sessions were seen for impulse during the isometric squat ( p = 0.04; effect size = –0.60) but only when calculating from the best trial. When computing the direction of asymmetry across test sessions, levels of agreement were fair to substantial for the isometric squat (Kappa = 0.29–0.64), substantial for the CMJ (Kappa = 0.64–0.66) and fair to moderate for the DJ (Kappa = 0.36–0.56). These results show that when asymmetry is computed between test sessions, the group mean is generally devoid of systematic bias; however, the direction of asymmetry shows greater variability and is often inter-changeable. Thus, practitioners should consider both the direction and magnitude of asymmetry when monitoring inter-limb differences in healthy athlete populations.
机译:本研究的目的是确定用于量化不对称性的单边强度和功率测试的重测信度,并确定测试会话之间不对称性的大小和方向的一致性。 28名接受过娱乐训练的体育运动员在两个测试阶段中进行了单边等距深蹲,反跳动作(CMJ)和落跳动作(DJ)测试。从最佳试验和每次试验的三个试验的平均值中计算出肢间不对称性。使用组内相关系数(ICC),变异系数(CV)和标准测量误差(SEM)计算测试可靠性。另外,使用成对的样本t检验确定测试时段和Kappa系数之间的系统偏差,以报告不对称性如何持续一致地偏向同一侧。会话间和会话间的可靠性从中等到出色(ICC范围= 0.70–0.96),并且在所有测试中CV值的范围从3.7–13.7%。在等距下蹲期间的冲动中,测试会话之间的不对称性存在显着差异(p = 0.04;效果大小= –0.60),但仅在最佳试验中计算出。在计算整个测试期间的不对称方向时,等距下蹲的同意水平大致合理(Kappa = 0.29–0.64),CMJ的大致同意水平(Kappa = 0.64–0.66),DJ基本同意程度适中(Kappa = 0.36-0.56)。这些结果表明,在测试会话之间计算不对称性时,组均值通常没有系统性偏倚。但是,不对称方向显示出更大的可变性,并且经常可以互换。因此,从业者在监测健康运动员群体的肢间差异时应同时考虑不对称的方向和大小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号