首页> 外文期刊>Pramana >Scattered ionizing radiations from low-energy focus plasma and radiation dosimetery assessment
【24h】

Scattered ionizing radiations from low-energy focus plasma and radiation dosimetery assessment

机译:低能聚焦等离子体和辐射剂量法评估得出的散射电离辐射

获取原文
       

摘要

Scattered ionizing radiation emissions from a low-energy plasma focus (0.1 kJ Mather-type) device operating with different gases were studied. The plasma focus device was powered by a capacitor bank of 1 e???F at 18 kV maximum charging voltage. The radiation emissions were investigated using time-integrated thermoluminescence TLD-500. These detectors were calibrated against standard X-ray machine as well as standard e??? sources (60Co and 137Ca). Calibration of detectors showed linear relation over all the region of measurements. It was found that radiation levels would be minimum for different gases, when the gas pressure was between 0.5 and 0.8 Torr. Only helium deviated from this phenomenon as it gave maximum radiation level at 0.8 Torr pressure. It was also found that, for all the gases used, the radiation levels were maximum when the applied voltage was 15 keV.
机译:研究了在不同气体下工作的低能量等离子体聚焦(0.1 kJ马瑟型)设备的散射电离辐射发射。等离子聚焦装置由1 e?F的电容器组以18 kV的最大充电电压供电。使用时间积分热发光TLD-500对辐射发射进行了研究。这些探测器根据标准的X射线机以及标准的e射线机进行了校准。源(60Co和137Ca)。检测器的校准显示了在所有测量区域上的线性关系。发现当气压在0.5和0.8托之间时,对于不同的气体,辐射水平将是最小的。只有氦气偏离了这种现象,因为氦气在0.8托压力下具有最大辐射水平。还发现,对于所有使用的气体,当施加电压为15 keV时,辐射水平最大。