首页> 外文期刊>Physics in Medicine >Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous medium
【24h】

Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous medium

机译:评估蒙特卡洛Geant4预测异质介质中光子束剂量分布的能力

获取原文
           

摘要

The aim of this study is the assessment of the Geant4 capabilities in accurately modeling of dose distribution in a heterogeneous water phantom. In this purpose, a Geant4 user code has been designed and developed to enable an accurate modeling of cross beam profiles in a heterogeneous water phantom deposited by a 12?MV photon beam emitted by a Saturne 43 Linac head and configuring a 10?×?10?cm 2 radiation field. The calculated cross beam profiles at two distinct depths (22?cm and 25?cm), were compared to the ones obtained with MCNPX code. Our findings show that the shapes of dosimetric curves at two distinct depths calculated with Geant4 code and the ones obtained by MCNPX code are in a very good agreement. However, the Geant4 code seems painfully slow when calculating those dosimetric curves and its associated statistical uncertainties don't seem to reach 1% after two weeks of calculations. To deal with this issue, we suggest that a new variance reduction technique specially addressed for dose calculation in a heterogeneous medium must be developed by the Geant4 collaboration, in order to decrease the required computing time and to improve the statistical of calculations. Highlights ? Assessment of the Geant4 capabilities in accurately modeling of dose distribution in a heterogeneous water phantom. ? A comparison with MCNPX has confirmed the limitations of Geant4 code to predicting dose in a heterogeneous medium. ? We suggest that a new vrt addressed for calculation in a heterogeneous medium must be developed by Geant4 collaboration.
机译:这项研究的目的是评估Geant4对异质水体模中剂量分布进行精确建模的能力。为此,已经设计并开发了Geant4用户代码,以实现对由Saturne 43直线加速器喷头发射的12?MV光子束沉积的异质水体模中的横梁轮廓进行精确建模并配置10?×?10的能力。 ?cm 2的辐射场。将计算出的两个不同深度(22?cm和25?cm)的横梁轮廓与使用MCNPX代码获得的横梁轮廓进行比较。我们的发现表明,用Geant4代码计算出的两个不同深度处的剂量曲线与通过MCNPX代码获得的剂量曲线具有很好的一致性。但是,当计算这些剂量曲线时,Geant4代码似乎非常缓慢,并且经过两周的计算,其相关的统计不确定性似乎未达到1%。为了解决这个问题,我们建议必须与Geant4合作开发一种新的方差减少技术,该技术专门针对异构介质中的剂量计算,以减少所需的计算时间并改善计算的统计数据。强调 ?评估Geant4在异构水体模型中剂量分布的精确建模中的能力。 ?与MCNPX的比较已经证实了Geant4代码在预测异质培养基中的剂量方面的局限性。 ?我们建议必须通过Geant4合作开发用于在异构介质中进行计算的新vrt。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号