Objective: To explore the treatment effects of HydroCoil Embolic System (HES) on large- and medium-sized intracranial aneurysms.Methods: Fifty cases of intracranial aneurysm patients were retrospectively analyzed, in which 27 and 23 cases were treated with HES (n=27) and ordinary coils (n=23), respectively. All the patients were followed up for two years.Results: The 27 cases (54%, 27/50) treated with HES include 23 cases of densely packed occlusion (46%, 23/50) and 4 cases of subtotal occlusion (8%, 4/50). The 23 cases (46%, 23/50) treated with ordinary coils include 15 cases of densely packed occlusion (30%, 15/50) and 8 cases of subtotal occlusion (16%, 8/50).Conclusion: HydroCoil Embolic System (HES) may increase the ratio of densely packed occlusion and prevent the recurrence of large- and medium-sized intracranial aneurysms.doi: http://dx.doi.org/10.12669/pjms.296.3640How to cite this:Wei D, Wei C, Huang S,Lin Q, Wang Y. Comparison between effects of HydroCoil Embolic System and ordinary coil on large- and medium-sized intracranial aneurysms. Pak J Med Sci 2013;29(6):1334-1337. doi: http://dx.doi.org/10.12669/pjms.296.3640This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
机译:目的:探讨HydroCoil栓塞系统(HES)对大,中型颅内动脉瘤的治疗效果。方法:回顾性分析50例颅内动脉瘤患者,其中HES治疗27例和23例(n = 27)。 )和普通线圈(n = 23)。所有患者均接受了两年的随访。结果:HES治疗的27例(54%,27/50)包括23例致密性闭塞(46%,23/50)和4例次全闭塞(8% ,4/50)。普通线圈治疗的23例(46%,23/50)包括15例密密闭塞(30%,15/50)和8例小计闭塞(16%,8/50)。结论:HydroCoil栓塞系统(HES)可能会增加密集包扎的闭塞率并防止大中型颅内动脉瘤复发。doi:http://dx.doi.org/10.12669/pjms.296.3640如何引用此信息:Wei D,魏C,黄S,林Q,王Y. HydroCoil栓塞系统和普通线圈对大中型颅内动脉瘤的影响比较。 Pak J Med Sci 2013; 29(6):1334-1337。 doi:http://dx.doi.org/10.12669/pjms.296.3640这是根据知识共享署名许可(http://creativecommons.org/licenses/by/3.0)的条款分发的开放访问文章,只要适当引用了原始作品,便可以在任何介质中不受限制地使用,分发和复制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号