This paper is focused on indoor air quality study (IAQ) into a metallurgic industrialhall. A model (named INPOLL) for computing the time evolution of concentrations of various airpollutants in closed working areas was carried out. The model uses a partition of the working unit in aconvenient number of cells with known transfer and ventilation air fluxes. The hall is also supposedto communicate with its exterior, both by accidental air leakages and through the ventilation system.Then, a time-dependent injection of pollutants occurring in various sites of the working spacedetermines the subsequent evolution of pollutant concentrations in all the compartments of thepartition. Starting from some given set of background concentrations, the model can predict thevalues of the pollutant concentrations in each cell, at any time from the start. Maxima of pollutantconcentrations result when some furnace begins the discharging process. By varying the modelparameters (like the air currents for ventilation or the time delay between furnace discharges), one canobtain a process optimization from the point of view pollutant concentrations. The model is suitablefor dynamic simulations of indoor environmental dispersion of pollutants.
机译:本文将重点放在冶金工业车间的室内空气质量研究(IAQ)上。建立了一个用于计算封闭工作区域中各种空气污染物浓度随时间变化的模型(名为INPOLL)。该模型使用工作单元的分区来划分数量众多的单元,这些单元具有已知的传递和通风空气通量。大厅还应该通过偶然的漏气和通过通风系统与其外部进行通信,然后,在工作空间的不同位置发生随时间变化的污染物注入,确定分区中所有隔间中污染物浓度的后续变化。从一组给定的背景浓度开始,该模型可以从开始就随时预测每个单元格中污染物的浓度值。当某些熔炉开始排放过程时,会产生最大的污染物浓度。通过改变模型参数(例如通风的气流或炉子放电之间的时间延迟),可以从污染物浓度的角度获得工艺优化。该模型适用于污染物室内环境扩散的动态模拟。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号