摘要

A number of about 130 solid state nuclear track detectors (SSNTD) of CR39 typewere exposed in controlled conditions in a Radon Exposure Calibration chamber.The purpose of thework was to study the dependence of the response of the detector to the exposure conditions.Identically shaped CR39 detectors were placed in open cylindrical cups of various geometries (heightand diameter).For each geometry the side surface of the detector cup was coated with three materials,paper, plastic and aluminum.The effect of the coating of the detector cup on the plate-out of theradon decay products, as well as on the detector response was investigated for each geometry of thedetector cup.The dependence of the response on the geometry of the cup was also studied.
机译:在受控的条件下,在Radon暴露校准室中暴露了约130个CR39型固态核径迹探测器(SSNTD),目的是研究探测器响应对暴露条件的依赖性。将探测器放置在各种几何形状(高度和直径)的敞开圆柱杯中。对于每种几何形状,探测器杯的侧面均涂有纸,塑料和铝三种材料。对于探测器杯的每种几何形状,研究了the气衰变产物中的碳原子数以及探测器的响应。还研究了响应对杯几何形状的依赖性。